EPSON AcuLaser C1100 Revision B

TROUBLESHOOTING FIP according to the printer message 168

FIP-29

Panel Message
Jam E
Jam D, E
Possible parts that caused the error
Troubleshooting

ROLL ASSY PRE-REGI ROLL-PINCH

ROLL-REGI METAL ROLL REGI RUBBER

ACTUATOR-REGI SENSOR REGI

MOTOR-PH HARNESS-ASSY P/H1

HARNESS-ASSY P/H2 PWBA MCU

LV/HVPS HARNESS ASSY MAIN

Step Check Yes No
1Paper size check
Is the paper size compliant with the
specifications?
Go to Step[2]. Use paper of
size compliant
with the
specifications.
2Paper size setting check
Does the size of the paper in use match the
size of the paper set on the control panel?
Go to Step[4]. Change the
paper size
setting, and
proceed to step
[3].
3Does the error recur when a test print is
made by dialog operations? Go to Step[4]. End of
procedure
4Shape and operation check of ROLL ASSY
PRE-REGI and ROLL-PINCH
Open CHUTE ASSY-REAR.
Are ROLL ASSY PRE-REGI and ROLL-
PINCH attached correctly?
Also, do these parts rotate smoothly without
any dirt or damage?
Turn by hand to check.
Go to Step[5]. Replace or re-
attach ROLL in
question.
5Shape and operation check of ROLL-REGI
METAL and ROLL REGI RUBBER
Open CHUTE ASSY-REAR.
Are the ROLL-REGI and ROLL REGI
RUBBER attached correctly?
Also, do these parts rotate smoothly without
any dirt or damage?
Turn by hand to check.
Go to Step[6]. Replace or re-
attach ROLL in
question.
6Operation check of ACTUATOR-REGI
Does ACTUATOR-REGI move smoothly
without any damage? Does ACTUATOR-
REGI enter the sensor sensing area when there
is paper? Does it leave the sensor sensing area
when there is no paper?
Go to Step[7]. Replace
ACTUATOR-
REGI. (p.335)
7 Operation check of SENSOR REGI
The voltage of P408-12P408-11 on
PWBA MCU is 0 VDC when ACTUATOR
REGI enters the sensing area of SENSOR
REGI, and is 5 VDC when it leaves the
sensing area?
Go to Step[8]. Go to Step[11].
8
24 VDC power supply check to MOT OR-PH
The voltage of P409-6P409-5 on PWBA
MCU is 24 VDC?
Go to Step[9]. Go to Step[14].
9Continuity check of HARNESS-ASSY P/H1
Disconnect P/J405 and P/J604 from PWBA
MCU.
Do all of the wiring below have normal
continuity?
J409-1P604-6
J409-2P604-5
J409-3P604-4
J409-4P604-3
J409-5P604-2
J409-6P604-1
Go to Step[10]. Replace
HARNESS-
ASSY P/H1.
Step Check Yes No