EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY MSI 305
REINSTALLATION
1. Gently insert HARNESS-ASSY P/H 1 along the left side of MSI ASSY together
with MSI ASSY from the front of the main unit.
2. Insert MSI ASSY about halfway with the front of MSI ASSY lifted slightly to
avoid TIE PLATE under the main unit, and then bring out the connector of
HARNESS-ASSY P/H 1 from the hole on the main unit.
3. After matching MSI ASSY to the main unit attachment position, gently pull
HARNESS-ASSY P/H 1 from the outside to take up any slack inside the main
unit.
4. Fasten MSI ASSY to the main unit with the 6 screws (silver, with flange, tapping,
8 mm).
5. Connect connector (P/J408) and connector (P/J409) to PWBA MCU.
6. Fasten the harness of HARNESS-ASSY P/H 1 with the two clamps on CHASSIS
ESS.
7. Attach FRAME ASSY-PH. (p.327)
8. Attach COVER FRONT L and COVER FRONT ASSY U. (p.292)
9. Attach COVER MSI. (p.291)
10. Attach COVER ASSY LH. (p.295)
11. Attach COVER ASSY RH. (p.301)
1
Figure 4-24. Reinstallation of MSI ASSY
C A U T IO N When performing the following work, take care to prevent the
cable tie that bundles the harness of HARNESS-ASSY P/H 1
from being caught on the holes, etc. on the main unit.
When performing the following work, take care to prevent the
HARNESS-ASSY P/H 1 from being sandwiched between the
main unit and MSI ASSY.
Table 4-2. Symptoms when the connector is loose
Connector
No. Panel Indication Symptom Error Caused by Connector
Disconnection
P/J408 E Open Printing is not
possible. Paper Feeder Rear Cover is open.
P/J409 Service Req E511 Printing is not
possible. Sensor TR0 error
Leg_Sec03_507EB
CAUTION
[2)-1][2)-2]
[3)]
[1)]