EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY FUSER 389
REINSTALLATION
1. Attach Spring to Actuator.
2. With Chute on FUSER ASSY open, insert the shaft of Actuator to the main unit,
and attach together with Spring.
3. Match the connector and the boss on the FUSER ASSY side with the connector
and the hole on the main unit side, and attach FUSER ASSY.
4. Return the levers on both sides of FUSER ASSY, and firmly lock on the main unit.
5. Open COVER ASSY TOP.
6. Attach COVER TOP SIDE L. (p.286)
7. Close COVER ASSY TOP.
8. In the case of the standard specification, close COVER FUSER.
9. In the case of the DUPLEX specification, close DUPLEX ASSY.
C A U T IO N COVER TOP SIDE L cannot be attached on the main unit unless
the lever on FUSER ASSY is firmly locked.
C A U T IO N When replaced FUSER ASSY with a new one, clear the life counter
to zero. (Refer to “6.3.1 Maintenance Menu Items” (p497))