EPSON AcuLaser C1100 Revision B

MAINTENANCE Consumables and Components needing Periodic Replacement 507

6.5.2 Regular Replacement Parts
*1:The same function is also available in the reset menu.

Table 6-6. Maintenance Information on Regular Replacement Parts

Part Name Part Code Life (Pages) Service life indication Part to be replaced at
the same time Remedy after Replacement Remarks
FUSER ASSY 2090471 100,000 Worn Fuser 2ND BTR ASSY Execute “Reset Fuser Counter” in the
maintenance mode to reset the life
counter. *1
While it can still be printed, it is desirable to
replace the unit. If printing is continued, the
FUSER UNIT breaks down for the last time
and the following troubles may be occurred.
Fusing defect
Stain of the bac k s ide
Paper jam in the fusing section
HOUSING ASSY-
DEVE
K1292991 100,000 Worn K Dev Unit PIVOT AD Execute “Reset X DvlpCounter” (X=Y,
M, C, K) in the maintenance mode to
reset the life counter.
After executing the counter reset, open
and close the cover A. Do not turn the
printer off until the engine completely
stops.
While it can still be printed, it is
desirable to replace the unit.
The “PIVOT AD” is packed with the
ASP “HOUSING ASSY-DEVE”.
Y1292994
66,700
Worn Y Dev Unit PIVOT AD
M1292996 Worn M Dev Unit PIVOT AD
C1292999 Worn C Dev Unit PIVOT AD
2ND BTR ASSY 1292981 100,000 --- FUSER ASSY
Execute “Reset 2ndBTRCounter” in the
maintenance mode to reset the life
counter.
After executing the counter reset, open
and close the cover A. Do not turn the
printer off until the engine completely
stops.
While it can still be printed, it is desirable to
replace the unit.