EPSON AcuLaser C1100 Revision B

TROUBLESHOOTING FIP according to the printer message 192

FIP-39

Panel Message
Service Req E517
Possible parts that caused the error
Troubleshooting

HARNESS ASSY MAIN HARNESS-ASSY FEED 1

HARNESS-ASSY FEED 2 PWBA TRAY 500

PWBA MCU LV/HVPS
Step Check Yes No
1Check of Feeder attachment on printer
Remove and re-attach Feeder.
Does the error recur when the power is turned
ON?
Go to Step [2]. End of
procedure
2
Continuity check of HARNESS ASSY MAIN
Remove Feeder from the printer.
Disconnect P/J421 from PWBA MCU.
Is the continuity normal between all terminals
of J421J608 (connector on the printer to
connect Feeder)?
Go to Step [3]. Repair broken
or shorted part.
3Does the error recur when the power is
turned ON? Go to Step [4]. End of
procedure
4Continuity check of HARNESS-ASSY
FEED 1 of Feeder
Remove Feeder.
Disconnect P/J435 from PWBA TRAY 500.
Is the continuity normal between all terminals
of J435P608 (connector on Feeder to be
connected to the printer)?
Go to Step [5]. Replace
HARNESS-
ASSY FEED 1.
(p.462)
5
Check after replacement of PWBA TRAY 500
Replace PWBA TRAY 500. (p.456)
Does the error recur when the power is turned
ON?
Go to Step [6]. End of
procedure
6Check after replacement of PWBA MCU
Replace PWBA MCU. (p.404)
Does the error recur when the power is turned
ON?
Go to Step [7]. End of
procedure
7
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Is the continuity normal between all terminals
of J410J502?
Replace LV/
HVPS. (p.407) Repair broken
or shorted part.
Step Check Yes No