EPSON AcuLaser C1100 Revision B

TROUBLESHOOTING FIP according to the printer message 208

FIP-52

Panel Message
Service Req E520
Possible parts that caused the error
Troubleshooting
HARNESS ASSY MAIN MOT ASSY MICRO

SENSOR 2BTR RETRACT HARNESS ASSY ADC

PWBA MCU LV/HVPS
Step Check Yes No
1Check of DRIVE ASSY BTR attachment
Is the DRIVE ASSY BTR attached correctly?
Go to Step [2]. Re-attach, and
go to step [2].
2Check of 2ND BTR ASSY attachment
Is 2ND BTR ASSY attached correctly?
Go to Step [4]. Re-attach, and
go to step [3].
3Does the error recur when a test print is
made? Go to Step [4]. End of
procedure
4
Continuity check of HARNESS ASSY MAIN
Disconnect the P/J403 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J403-1J600-3
J403-2J600-2
J403-3J600-1
Go to Step [5]. Repair broken
or shorted part.
524 VDC power supply check to MOT ASSY
MICRO (2nd BTR Retract Motor)
The voltage of P403-3P403-2 on PWBA
MCU is 24 VDC?
Go to Step [6]. Go to Step [11].
6Check after replacement of MOT ASSY
MICRO
Replace MOT ASSY MICRO. (p.399)
Does the error recur when a test print is made?
Go to Step [7]. End of
procedure
75 VDC power supply check to SENSOR
2BTR RETRACT
The voltage of P418-4P418-5 on PWBA
MCU is 5 VDC?
Go to Step [8]. Go to Step [11].
8Continuity check of HARNESS ASSY ADC
Disconnect the P/J418 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J418-4J112-3
J418-5J112-2
J418-6J112-1
Go to Step [9]. Replace
HARNESS
ASSY ADC.
9Check after replacement of SENSOR 2BTR
RETRACT
Replace SENSOR 2BTR RETRACT. (p.356)
Does the error recur when a test print is made?
Go to Step [10]. End of
procedure
10 Check after replacement of PWBA MCU
Replace PWBA MCU. (p.404)
Does the error recur when a test print is made?
Go to Step [12]. End of
procedure
Step Check Yes No