EPSON AcuLaser C1100 Revision B

DISASSEMBLY AND ASSEMBLY PH ASSY 328

REINSTALLATION
1. Attach CHUTE ASSY-REAR. (p.325)
2. Turn FRAME ASSY-PH 90° in the direction of the arrow, and connect connector
(P/J603) and connector (P/J604) connected to the main unit.
3. Open CHUTE ASSY-REAR.
4. While pushing down the film part of the HOLDER ASSY RETARD MSI, match
FRAME ASSY-PH with the attachment position of the main unit.
5. Fasten FRAME ASSY-PH to the main unit with the 4 screws (silver, with flange,
8 mm).
6. Close CHUTE ASSY-REAR.
7. In the case of the standard specification, attach COVER-PH. (p.324)
8. In the case of the DUPLEX specification, attach DUPLEX ASSY. (p.412)
Figure 4-44. Reinstallation of FRAME ASSY-PH
Figure 4-45. Check point after installing FRAME ASSY-PH
C A U T IO N When performing the following work, take care to prevent the
harness from being sandwiched between the main unit and FRAME
ASSY-PH.
C A U T IO N Make sure to confirm that the film part of the HOLDER ASSY
RETARD MSI is located lateral to the FRAME ASSY-PH after
installing the FRAME ASSY-PH to the main unit. If the film part
gets through the inside of the FRAME ASSY-PH, a paper jam is
occurred by blocking a paper feeding path. (See Figure 4-45)
Leg_03_510EB

[2)]

[4)-1]

[4)-2]

OK NG
HOLDER ASSY RETARD MSI
Film part