SJ200 Inverter
|
| “B” Function | Run |
| Defaults |
| ||
|
|
|
|
|
|
|
| |
Func. | Name / |
| Description | Mode |
| Units | ||
| Edit |
| ||||||
Code | SRW Display | (EU) | (USA) |
| ||||
|
|
|
| |||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
B031 | Software lock mode | Prevents parameter changes, in | ✘ | 01 | 01 |
| — | |
| selection |
| four options, option codes: |
|
|
|
|
|
|
|
| 00... all parameters except |
|
|
|
|
|
| MD1 |
|
|
|
|
| ||
| B031 are locked when [SFT] |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
| terminal is ON |
|
|
|
|
|
|
|
| 01... all parameters except |
|
|
|
|
|
|
|
| B031 and output frequency |
|
|
|
|
|
|
|
| F001 when [SFT] terminal is |
|
|
|
|
|
|
|
| ON |
|
|
|
|
|
|
|
| 02... all parameters except |
|
|
|
|
|
|
|
| B031 are locked |
|
|
|
|
|
|
|
| 03... all parameters except |
|
|
|
|
|
|
|
| B031 and output frequency |
|
|
|
|
|
|
|
| F001 setting are locked |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: To disable parameter editing when using B031 lock modes 00 and 01, assign the [SFT] function to one of the intelligent input terminals.