SJ200 Inverter
The inverter can store up to 16 different target frequencies (speeds) that the motor output uses for
Note: When choosing a subset of speeds to use, always start at the top of the table, and with the
The example with eight speeds in the figure below shows how input switches configured for
3rd Speed
7th 5th 2nd 1st 6th 4th 0th
1 [CF1] 0
1 [CF2] 0
1 [CF3] 0
1 [FWD] 0
t
Multi- | Input Function | |||
|
|
|
| |
speed | CF4 | CF3 | CF2 | CF1 |
| ||||
|
|
|
|
|
|
|
|
|
|
Speed 0 | 0 | 0 | 0 | 0 |
|
|
|
|
|
Speed 1 | 0 | 0 | 0 | 1 |
|
|
|
|
|
Speed 2 | 0 | 0 | 1 | 0 |
|
|
|
|
|
Speed 3 | 0 | 0 | 1 | 1 |
|
|
|
|
|
Speed 4 | 0 | 1 | 0 | 0 |
|
|
|
|
|
Speed 5 | 0 | 1 | 0 | 1 |
|
|
|
|
|
Speed 6 | 0 | 1 | 1 | 0 |
|
|
|
|
|
Speed 7 | 0 | 1 | 1 | 1 |
|
|
|
|
|
Speed 8 | 1 | 0 | 0 | 0 |
|
|
|
|
|
Speed 9 | 1 | 0 | 0 | 1 |
|
|
|
|
|
Speed 10 | 1 | 0 | 1 | 0 |
|
|
|
|
|
Speed 11 | 1 | 0 | 1 | 1 |
|
|
|
|
|
Speed 12 | 1 | 1 | 0 | 0 |
|
|
|
|
|
Speed 13 | 1 | 1 | 0 | 1 |
|
|
|
|
|
Speed 14 | 1 | 1 | 1 | 0 |
|
|
|
|
|
Speed 15 | 1 | 1 | 1 | 1 |
|
|
|
|
|
NOTE: Speed 0 is set by the A020 parameter value.
Operations and
Option | Terminal | Function Name | Input | Description | |
Code | Symbol | State | |||
|
| ||||
|
|
|
|
| |
|
|
|
|
| |
02 | CF1 | ON | Binary encoded speed select, Bit 0, logical 1 | ||
|
| Bit 0 (LSB) |
|
| |
|
| OFF | Binary encoded speed select, Bit 0, logical 0 | ||
|
|
| |||
|
|
|
|
| |
03 | CF2 | ON | Binary encoded speed select, Bit 1, logical 1 | ||
|
| Bit 1 |
|
| |
|
| OFF | Binary encoded speed select, Bit 1, logical 0 | ||
|
|
| |||
|
|
|
|
| |
04 | CF3 | ON | Binary encoded speed select, Bit 2, logical 1 | ||
|
| Bit 2 |
|
| |
|
| OFF | Binary encoded speed select, Bit 2, logical 0 | ||
|
|
| |||
|
|
|
|
| |
05 | CF4 | ON | Binary encoded speed select, Bit 3, logical 1 | ||
|
| Bit 3 (MSB) |
|
| |
|
| OFF | Binary encoded speed select, Bit 3, logical 0 | ||
|
|
|
Monitoring