Maintenance and Inspection
Monthly and Yearly Inspection Chart
Item Inspected | Check for... | Inspection Cycle | Inspection | Criteria | |||
|
| ||||||
Month | Year | Method | |||||
|
|
|
| ||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
| Ambient | Extreme | ✔ |
| Thermometer, | Ambient temperature | |
| environment | temperatures |
|
| hygrometer | between | |
|
| & humidity |
|
|
| ||
|
|
|
|
|
|
| |
| Major devices | Abnormal | ✔ |
| Visual and aural | Stable environment for | |
Overall |
| noise & vib. |
|
|
| electronic controls | |
|
|
|
|
|
|
| |
| Power supply | Voltage | ✔ |
| Digital volt meter, | 200V class: | |
| voltage | tolerance |
|
| measure between | 200 to 240V 50/60 Hz | |
|
|
|
|
| inverter terminals | 400V class: | |
|
|
|
|
| [L1], [L2], [L3] | 380 to 460V 50/60 Hz | |
|
|
|
|
|
|
| |
| Ground | Adequate |
| ✔ | Digital volt meter, | 5 Meg. Ohms or greater | |
| Insulation | resistance |
|
| GND to terminals |
| |
|
|
|
|
|
|
| |
| Mounting | No loose |
| ✔ | Torque wrench | M3: 0.5 – 0.6 Nm | |
|
| screws |
|
|
| M4: 0.98 – 1.3 Nm | |
|
|
|
|
|
| M5: 1.5 – 2.0 Nm | |
|
|
|
|
|
|
| |
| Components | Overheating |
| ✔ | Thermal trip events | No trip events | |
|
|
|
|
|
|
| |
| Housing | Dirt, dust |
| ✔ | Visual | Vacuum dust and dirt | |
|
|
|
|
|
|
| |
| Terminal block | Secure |
| ✔ | Visual | No abnormalities | |
Main |
| connections |
|
|
|
| |
|
|
|
|
|
| ||
circuit | Smoothing | Leaking, | ✔ |
| Visual | No abnormalities | |
| capacitor | swelling |
|
|
|
| |
|
|
|
|
|
|
| |
| Relay(s) | Chattering |
| ✔ | Aural | Single click when | |
|
|
|
|
|
| switching ON or OFF | |
|
|
|
|
|
|
| |
| Resistors | Cracks or |
| ✔ | Visual | Use Ohm meter to | |
|
| discoloring |
|
|
| check braking resistors | |
|
|
|
|
|
|
| |
| Cooling fan | Noise | ✔ |
| Power down, | Rotation must be | |
|
|
|
|
| manually rotate | smooth | |
|
|
|
|
|
|
| |
|
| Dust | ✔ |
| Visual | Vacuum to clean | |
|
|
|
|
|
|
| |
| Overall | No odor, |
| ✔ | Visual | No abnormalities | |
Control |
| discoloring, |
|
|
|
| |
| corrosion |
|
|
|
| ||
circuit |
|
|
|
|
|
| |
Capacitor | No leaks or | ✔ |
| Visual | Undistorted appearance | ||
|
| ||||||
|
| deformation |
|
|
|
| |
|
|
|
|
|
|
| |
Display | LEDs | Legibility | ✔ |
| Visual | All LED segments work | |
|
|
|
|
|
|
|
Troubleshooting Maintenance and
Note 1: The life of a capacitor is affected by the ambient temperature. See “Capacitor Life Curve” on page
Note 2: The inverter must be cleaned periodically. If dust accumulates on the fan and heat sink, it can cause overheating of the inverter.