Inverter Mounting | and Installation |
|
|
Set the Number of Motor Poles - The motor’s internal winding arrangement determines its number of magnetic poles. The specifications label on the motor usually indicates the number of poles. For proper operation, verify the parameter setting matches the motor poles. Many industrial motors have four poles, corresponding to the default setting in the inverter (H004).
Follow the steps in the table below to verify the motor poles setting and change it if necessary (the table resumes action from the end of the previous table.)
Action | Display | Func./Parameter |
|
|
|
(Starting point) |
|
| b 0 1 2 | Level of electronic thermal setting | ||
|
|
| ||||
|
|
|
|
|
|
|
Press the FUNC. key. |
|
| b – – – | “B” Group selected | ||
|
|
| ||||
|
|
|
|
|
|
|
Press the | 1 | key two times. | H – – – | “H” Group selected | ||
| ||||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
Press the FUNC. key. |
|
| H 0 0 3 | First “H” parameter | ||
|
|
| ||||
|
|
|
|
|
|
|
Press the | 1 | key once. | H 0 0 4 | Motor poles parameter | ||
| ||||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
Press the FUNC. key. |
|
| 4 | 2 = 2 poles | ||
|
| 4 = 4 poles (default) | ||||
|
|
|
|
|
| 6 = 6 poles |
|
|
|
|
|
| 8 = 8 poles |
|
|
|
|
|
|
|
Press the | 1 | or | 2 | key as needed. | 4 | Set to match your motor (your |
display may be different) | ||||||
|
|
|
|
| ||
|
|
|
|
|
|
|
Press the STR | key. |
| H 0 0 4 | Stores parameter, returns to “H” | ||
| Group list |
This step concludes the parameter setups for the inverter. You are almost ready to run the motor for the first time!
TIP: If you became lost during any of these steps, first observe the state of the PRG LED. Then study the “Keypad Navigational Map” on page