“C” Group: IntelligentTerminal Functions
Configuring | Drive Parameters |
|
|
Output Terminal Configuration
The inverter provides configuration for logic (discrete) and analog outputs, shown in the table below.
|
| “C” Function | Run |
| Defaults |
| ||
|
|
|
|
|
|
|
| |
Func. | Name / |
| Description | Mode |
| Units | ||
| Edit |
| ||||||
Code | SRW Display | (EU) | (USA) |
| ||||
|
|
|
| |||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
C021 | Terminal [11] function |
| ✘ | 01 | 01 |
| — | |
|
|
|
|
| [FA1] | [FA1] |
|
|
| FA1 |
|
|
|
| |||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
C022 | Terminal [12] function | 10 programmable functions | ✘ | 00 | 00 |
| — | |
|
|
|
| [RUN] | [RUN] |
|
| |
| RUN | available for logic (discrete) |
|
|
| |||
|
|
|
|
|
| |||
|
|
| outputs (see next section) |
|
|
|
|
|
C026 | Alarm relay terminal | ✘ | 05 | 05 |
| — | ||
|
| |||||||
| function |
|
|
| [AL] | [AL] |
|
|
|
|
|
|
|
|
|
|
|
| AL |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
C028 | [AM] signal selection | Two available functions: | ✘ | 00 | 00 |
| — | |
|
|
| 00... Actual motor speed |
| output | output |
|
|
| F |
|
|
| ||||
| 01... Motor current |
| freq. | freq. |
|
| ||
|
|
|
|
|
| |||
|
|
| (see after next section) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The output logic convention is programmable for terminals [11], [12], and the alarm relay terminals. The
|
| “C” Function | Run |
| Defaults |
| |||
|
|
|
|
|
|
|
|
| |
Func. |
| Name / |
| Description | Mode |
| Units | ||
|
| Edit |
| ||||||
Code | SRW Display |
| (EU) | (USA) |
| ||||
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
C031 | Terminal [11] active | Select logic convention, two | ✘ | 00 | 00 |
| — | ||
| state |
| option codes: |
|
|
|
|
| |
|
|
| 00 | ... normally open (NO) |
|
|
|
|
|
| NO |
|
|
|
|
| |||
| 01 | ... normally closed (NC) |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
C032 | Terminal [12] active | Select logic convention, two | ✘ | 00 | 00 |
| — | ||
| state |
| option codes: |
|
|
|
|
| |
|
|
| 00 | ... normally open (NO) |
|
|
|
|
|
| NO |
|
|
|
|
| |||
| 01 | ... normally closed (NC) |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
C036 | Alarm relay active state | Select logic convention, two | ✘ | 01 | 01 |
| — | ||
|
|
| option codes: |
|
|
|
|
| |
| NC |
|
|
|
|
| |||
| 00 | ... normally open (NO) |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
| 01 | ... normally closed (NC) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|