SJ200 Inverter
Using the Front Panel Keypad
Please take a moment to familiarize yourself with the keypad layout shown in the figure below. The display is used in programming the inverter’s parameters, as well as monitoring specific parameter values during operation.
Display Units (Hertz / Amperes) LEDs | Power LED | Alarm LED | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| Run/Stop LED | ||
Parameter Display |
|
|
|
| HITACHI | POWER |
|
| ||||||
|
|
|
|
| ||||||||||
|
|
|
| ALARM |
|
|
| |||||||
|
|
|
| HITACHI |
| Hz |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| 5 0.0 |
| A |
|
|
|
|
|
| Program/Monitor LED | ||
Run Key Enable LED |
|
| RUN |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| RUN | STOP | PRG |
|
|
|
|
|
| Potentiometer Enable LED | |||
|
|
|
| RESET |
|
|
|
|
|
|
| |||
Run Key |
|
|
| FUNC | 1 2 | STR |
|
|
|
|
|
| Potentiometer | |
|
|
|
|
|
|
|
| |||||||
Stop/Reset Key | Function key | Up/Down keys | Store key | |||||||||||
|
Key and Indicator Legend
•Run/Stop LED - ON when the inverter output is ON and the motor is developing torque (Run Mode), and OFF when the inverter output is OFF (Stop Mode).
•Program/Monitor LED - This LED is ON when the inverter is ready for parameter editing (Program Mode). It is OFF when the parameter display is monitoring data (Monitor Mode).
Installation and | Mounting Inverter |
|
|
•Run Key Enable LED - is ON when the inverter is ready to respond to the Run key, OFF when the Run key is disabled.
•Run Key - Press this key to run the motor (the Run Enable LED must be ON first). Parameter F004, Keypad Run Key Routing, determines whether the Run key generates a Run FWD or Run REV command.
•Stop/Reset Key - Press this key to stop the motor when it is running (uses the programmed deceleration rate). This key will also reset an alarm that has tripped.
•Potentiometer - Allows an operator to directly set the motor speed when the potenti- ometer is enabled for output frequency control.
•Potentiometer Enable LED - ON when the potentiometer is enabled for value entry.
•Parameter Display - A
•Display Units, Hertz/Amperes - One of these LEDs will be ON to indicate the units associated with the parameter display.
•Power LED - This LED is ON when the power input to the inverter is ON.
•Alarm LED - ON when an inverter trip is active (alarm relay contacts will be closed).
•Function Key - This key is used to navigate through the lists of parameters and functions for setting and monitoring parameter values.
• Up/Down ( 1 , 2 ) Keys - Use these keys alternately to move up or down the lists of parameter and functions shown in the display, and increment/decrement values.
•Store ( STR ) Key - When the unit is in Program Mode and you have edited a parameter value, press the Store key to write the new value to the EEPROM.