“A” Group: Standard Functions
Configuring | Drive Parameters |
|
|
|
| “A” Function | Run |
| Defaults |
| ||
|
|
|
|
|
|
|
| |
Func. | Name / | Description | Mode |
| Units | |||
Edit |
| |||||||
Code | SRW Display | (EU) | (USA) |
| ||||
|
|
|
| |||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
A242 | Manual torque boost | Can boost starting torque | ✔ | 0.0 | 0.0 |
| % | |
| value, 2nd motor | between 0 and 20% above |
|
|
|
|
| |
|
|
| normal V/f curve, |
|
|
|
|
|
| 2VBst V | 0000.0% |
|
|
|
|
| |
| range is 0.0 to 20.0% |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
A043 | Manual torque boost | Sets the frequency of the V/f | ✔ | 3.0 | 3.0 |
| % | |
| frequency adjustment | breakpoint A in graph (top of |
|
|
|
|
| |
|
|
| previous page) for torque |
|
|
|
|
|
| 0003.0% |
|
|
|
|
| ||
| boost, range is 0.0 to 50.0% |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
A243 | Manual torque boost | Sets the frequency of the V/f | ✔ | 0.0 | 0.0 |
| % | |
| frequency adjustment, | breakpoint A in graph (top of |
|
|
|
|
| |
| 2nd motor |
| previous page) for torque |
|
|
|
|
|
|
|
| boost, range is 0.0 to 50.0% |
|
|
|
|
|
| 2MBst F | 0000.0% |
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
A044 | V/f characteristic curve | Two available V/f curves; | ✘ | 02 | 02 |
| — | |
| selection |
| three select codes: |
|
|
|
|
|
|
|
| 00... Constant torque |
|
|
|
|
|
| CTRL |
|
|
|
|
| ||
| 01... Reduced torque |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
| 02... Intelligent sensorless |
|
|
|
|
|
|
|
| vector control (iSLV) |
|
|
|
|
|
|
|
|
|
|
|
|
| |
A244 | V/f characteristic curve | Two available V/f curves; | ✘ | 02 | 02 |
| — | |
| selection, 2nd motor | three select codes: |
|
|
|
|
| |
|
|
| 00... Constant torque |
|
|
|
|
|
| 2CTRL |
|
|
|
|
| ||
| 01... Reduced torque |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
| 02... Intelligent sensorless |
|
|
|
|
|
|
|
| vector control (iSLV) |
|
|
|
|
|
|
|
|
|
|
|
|
| |
A045 | V/f gain setting | Sets voltage gain of the | ✔ | 100. | 100. |
| % | |
|
|
| inverter, range is 20. to 100.% |
|
|
|
|
|
| 00100% |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
A046 | Automatic torque boost | Sets torque boost voltage gain | ✔ | 100 | 100 |
| — | |
| voltage gain |
| of the inverter, |
|
|
|
|
|
|
|
| range is 0 to 255 |
|
|
|
|
|
| 0100% |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
A246 | Automatic torque boost | Sets torque boost voltage gain | ✔ | 100 | 100 |
| — | |
| voltage gain, 2nd motor | of the inverter, |
|
|
|
|
| |
|
|
| range is 0 to 255 |
|
|
|
|
|
| 2ABst V | 0100% |
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
A047 | Automatic torque boost | Sets torque boost slip gain of | ✔ | 100 | 100 |
| — | |
| slip gain |
| the inverter, |
|
|
|
|
|
|
|
| range is 0 to 255 |
|
|
|
|
|
| 00100% |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
A247 | Automatic torque boost | Sets torque boost slip gain of | ✔ | 100 | 100 |
| — | |
| slip gain, 2nd motor | the inverter, |
|
|
|
|
| |
|
|
| range is 0 to 255 |
|
|
|
|
|
| 2ABst S1 | 00100% |
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|