2–20

Inverter Mounting

and Installation

 

 

Step-by-Step Basic Installation

Please use the terminal arrangement below corresponding to your inverter model.

Inverter models SJ200–002NFEF/NFU to –005NFEF/NFU

Jumper

RB +1 + –

L1 L2 N/L3 U/T1 V/T2 W/T3

Chassis

Ground

Inverter models SJ200–007NFEF to –022NFEF, –007NFU to –037LFU, –004HFEF/HFU to –040HFEF/HFU

Jumper

 

 

+1

+

 

 

RB

 

 

Chassis

NFEF, NFU

L1

L2

N/L3

U/T1

V/T2

W/T3

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LFU, HFEF, HFU

L1

L2

L3

U/T1

V/T2

W/T3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter models SJ200–055HFEF/HFU, –075HFEF/HFU

L1 L2 L3 U/T1 V/T2 W/T3

+1 + – RB

JumperChassis

Ground

NOTE: An inverter powered by a portable power generator may receive a distorted power waveform, overheating the generator. In general, the generator capacity should be five times that of the inverter (kVA).

CAUTION: Be sure that the input voltage matches the inverter specifications:

Single/Three phase 200 to 240 V 50/60 Hz (up to 2.2kW) for NFEF/NFU models

Three phase 200 to 240V 50/60Hz (above 2.2kW) for LFU models

Three phase 380 to 480 V 50/60Hz for HFEF models

CAUTION: Be sure not to power a three-phase-only inverter with single phase power. Otherwise, there is the possibility of damage to the inverter and the danger of fire.