3–23

SJ200 Inverter

Automatic Voltage Regulation (AVR) Function

The automatic voltage regulation (AVR) feature keeps the inverter output waveform at a relatively constant amplitude during power input fluctuations. This can be useful if the installation is subject to input voltage fluctuations. However, the inverter cannot boost its motor output to a voltage higher than the power input voltage. If you enable this feature, be sure to select the proper voltage class setting for your motor.

 

 

“A” Function

Run

 

Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Func.

Name /

 

Description

Mode

–FEF

–FU

 

Units

 

 

 

Edit

 

 

 

Code

SRW Display

 

(EU)

(USA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A081

AVR function select

 

Automatic (output) voltage

00

00

 

 

 

 

 

 

 

regulation, selects from three

 

 

 

 

 

 

 

 

AVR Mode

 

ON

 

 

 

 

 

 

 

 

 

type of AVR functions, three

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

option codes:

 

 

 

 

 

 

 

 

 

 

 

00... AVR enabled

 

 

 

 

 

 

 

 

 

 

 

01... AVR disabled

 

 

 

 

 

 

 

 

 

 

 

02... AVR enabled except

 

 

 

 

 

 

 

 

 

 

 

during deceleration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A082

AVR voltage select

 

200V class inverter settings:

230/

230/

 

V

 

 

 

 

 

 

....... 200/215/220/230/240

 

400

460

 

 

 

 

 

AVR AC

00230V

 

 

 

 

 

 

400V class inverter settings:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configuring Parameters Drive

 

 

 

 

....... 380/400/415/440/460/480