SJ200 Inverter
Terminal Dimensions and Torque Specs
The terminal screw dimensions for all SJ200 inverters are listed in table below. This information is useful in sizing spade lug or ring lug connectors for wire terminations.
CAUTION: Fasten the screws with the specified fastening torque in the table below. Check for any loosening of screws. Otherwise, there is the danger of fire.
|
|
|
|
| Models 002NF, | Models 007NF- |
| Models 055LF, |
|
|
| ||||||
|
|
| Number |
| 022NF, 037LF, |
| 075LF, 055HF, |
|
|
| |||||||
|
|
|
| 004NF, 005NF |
|
|
|
| |||||||||
|
|
|
| 004HF - 040HF |
| 075HF |
| Installationand | MountingInverter | ||||||||
| Connector | of Screw |
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Terminals |
| Screw | Width | Screw |
| Width |
| Screw |
| Width |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
| Diameter | (mm) | Diameter |
| (mm) |
| Diameter |
| (mm) |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Power Terminals | 12 |
| M3.5 | 7.1 | M4 | 9 |
| M5 |
| 13 |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Control Signal | 16 |
| M2 | — | M2 |
| — |
| M2 |
| — |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Alarm Signal | 3 |
| M3 | — | M3 |
| — |
| M3 |
| — |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ground Terminals | 2 |
| M4 | — | M4 |
| — |
| M5 |
| — |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| When connecting wiring, use the tightening torque listed in the following table to safely |
|
| |||||||||||||
|
| attach wiring to the connectors. |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| Screw | Tightening Torque | Screw |
| Tightening Torque |
| Screw |
| Tightening Torque |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| M2 | 0.2 N•m (max. 0.25 N•m) | M3.5 |
| 0.8 N•m (max. 0.9 N•m) |
| M5 | 2.0 N•m (max. 2.2 N•m) |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| M3 | 0.5 N•m (max. 0.6 N•m) | M4 |
| 1.2 N•m (max. 1.3 N•m) |
| — |
| — |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wire the Inverter Input to a Supply
Step 6: In this step, you will connect wiring to the
6input of the inverter. First, you must determine whether the inverter model you have requires
The wiring example to the right shows an SJ200 inverter wired for