“C” Group: IntelligentTerminal Functions
Miscellaneous Functions
Configuring | Drive Parameters |
|
|
The following table contains miscellaneous functions not in other function groups.
|
| “C” Function | Run |
| Defaults |
| ||||
|
|
|
|
|
|
|
|
|
| |
Func. | Name / |
|
| Description | Mode |
| Units | |||
|
| Edit |
| |||||||
Code | SRW Display |
| (EU) | (USA) |
| |||||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |||
C091 | Debug mode enable | Displays debug parameters. | ✔ | 00 | 00 |
| — | |||
|
|
|
| Two option codes: |
|
|
|
|
| |
| DBG Slct |
| OFF |
|
|
|
|
| ||
|
| 00 | ... Disable |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
| 01 | ... Enable |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
C101 | Up/Down memory |
| Controls speed setpoint for the | ✘ | 00 | 00 |
| — | ||
| mode selection |
| inverter after power cycle. Two |
|
|
|
|
| ||
|
|
|
| option codes: |
|
|
|
|
| |
| UP/DWN |
|
|
|
|
| ||||
| 00 | ... Clear last frequency |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
| (return to default frequency |
|
|
|
|
| |
|
|
|
| F001) |
|
|
|
|
| |
|
|
|
| 01 | ... Keep last frequency |
|
|
|
|
|
|
|
|
| adjusted by UP/DWN |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
C102 | Reset selection |
| Determines response to Reset | ✘ | 00 | 00 |
| — | ||
|
|
|
| input [RST]. |
|
|
|
|
| |
| RS Slct |
| ON |
|
|
|
|
| ||
|
| Three option codes: |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
| 00 | ... Cancel trip state at input |
|
|
|
|
|
|
|
|
| signal ON transition, stops |
|
|
|
|
| |
|
|
|
| inverter if in Run Mode |
|
|
|
|
| |
|
|
|
| 01 | ... Cancel trip state at signal |
|
|
|
|
|
|
|
|
| OFF transition, stops inverter if |
|
|
|
|
| |
|
|
|
| in Run Mode |
|
|
|
|
| |
|
|
|
| 02 | ... Cancel trip state at input |
|
|
|
|
|
|
|
|
| signal ON transition, no effect |
|
|
|
|
| |
|
|
|
| if in Run Mode |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|