3–37

SJ200 Inverter

 

 

 

“B” Function

Run

 

Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Func.

 

Name /

Description

Mode

–FEF

–FU

 

Units

 

 

 

Edit

 

 

 

Code

SRW Display

(EU)

(USA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B080

[AM] analog signal

Adjust of analog output at

100.

100.

 

 

 

 

gain

 

 

terminal [AM],

 

 

 

 

 

 

 

 

 

 

 

range is 0 to 255

 

 

 

 

 

 

 

 

AM-Adj

00100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B082

Start frequency adjust-

Sets the starting frequency for

0.5

0.5

 

Hz

 

 

 

ment

 

 

the inverter output, range is 0.5

 

 

 

 

 

 

 

 

 

 

 

to 9.9 Hz

 

 

 

 

 

 

 

 

fmin

0000.5Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B083

Carrier frequency

Sets the PWM carrier (internal

5.0

5.0

 

kHz

 

 

 

setting

 

switching frequency), range is

 

 

 

 

 

 

 

 

 

 

 

2.0 to 14.0 kHz

 

 

 

 

 

 

 

 

Carrier

0005.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B084

Initialization mode

Select the type of initialization

00

00

 

 

 

 

(parameters or trip

to occur, two option codes:

 

 

 

 

 

 

 

 

history)

 

00... Trip history clear

 

 

 

 

 

 

 

 

 

 

 

01... Parameter initialization

 

 

 

 

 

 

 

 

INIT Mode

TRP

 

 

 

 

 

 

 

 

02... Trip history clear and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parameter initialization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B085

Country code for initial-

Select default parameter values

01

02

 

 

Configuring ParametersDrive

 

ization

 

for country on initialization,

 

 

 

 

 

 

 

 

 

 

four options, option codes:

 

 

 

 

 

 

 

INIT

Slct

USA

 

 

 

 

 

 

 

00... Japan version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01... Europe version

 

 

 

 

 

 

 

 

 

 

 

02... US version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B086

Frequency scaling

Specify a constant to scale the

1.0

1.0

 

 

 

 

conversion factor

displayed frequency for D007

 

 

 

 

 

 

 

 

 

 

 

monitor, range is 0.1 to 99.9

 

 

 

 

 

 

 

 

Cnv Gain

0001.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B087

STOP key enable

Select whether the STOP key

00

00

 

 

 

 

 

 

 

 

on the keypad is enabled, two

 

 

 

 

 

 

 

 

STP Key

ON

 

 

 

 

 

 

 

 

option codes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00... enabled

 

 

 

 

 

 

 

 

 

 

 

01... disabled