Figure 7-1Rear Panel layout

Chapter 7---Troubleshooting

Figure 7-1Rear Panel layout

Control Out - The Control Out terminal is another RS232 port similar to the Terminal In port except that it can not be used to Import/Export setup data.

Tethered Remote Jack - The Model 250 projector is shipped with an IR Remote Control. This IR Remote can be used with an optional 150 ft. cable that will plug in the Tethered Remote Jack.

IR Detector - This sensor detects commands from the IR Remote Control included with the projector. There is another IR Detector on the front of the projector.

Switch Block - The Switch Block controls various parameters of the CPU. Most of the switches are for diagnostic functions performed at the factory and will not need to be changed. They should all be in the DOWN position. The switch that will be of most concern to the field technician is the #4 switch that controls the baud rate of importing and exporting data and software. The UP position sets the baud rate at 19200 BPS and the DOWN position is 9600 BPS. 9600 BPS (DOWN) is the factory default setting.