Chapter
!+5.1V for digital components
!+6.2V for CRT filaments
!±15V for analog circuits
!+80V supply used by the High Voltage Power Supply, Video Amplifier PCB, and the Horizontal/Vertical Deflection PCB.
LVPS - Service Adjustments
There are no service adjustments for the Low Voltage Power Supply.
LVPS - Remove and Replace
Tools Needed:
#2
Parts Needed:
Low Voltage Power Supply - p/n 102520
To remove the Low Voltage Power Supply:
1.Power off the projector by IR Remote or PC, and allow the cooling fans to run until they shut off.
2.Turn the AC Circuit Breaker to the OFF position and unplug the AC Power Cord.
3.Remove the front cover (see Projector Covers section 6.1).
4.Remove the
5.Remove the 5
6.Remove J76 (DC Output) and J75 (AC Input) from the left side of the Low Voltage Power Supply.
NOTE: These connectors may be a little difficult to remove and it may be necessary to pull the LVPS partly out of the chassis in order to get a better grip on the connectors.
7.Carefully slide the Low Voltage Power Supply out of the projector.
8.Reinstall the LVPS in reverse order. After installing a new LVPS, it may be necessary to
Arc Lamp Power Supply (ALPS)
ALPS - Main Functions:
!Provides ignition power to turn the Arc Lamp ON (via the Igniter).
!Provides steady state power to maintain the Arc Lamp operation.
Model 250 Service Manual |