Chapter 4---Optical
CAUTION! To avoid damaging the connector, grasp the ILA® assembly itself, not the connector at the top.
Figure 4-10 ILA® Assembly top view. The overlap screws shown are under the ILA® . They are visible only after the ILA® assembly is removed.
13.If the overlap is at the top or bottom, be sure the projector is level. Slide the spring clip (see Figure 4-10) at the top of the ILA® assembly back.
14.Loosen the two hex nuts, using a 4-mm hex-head wrench.
WARNING!!! Always wear an ANSI/ASTM 10,000 volt rated safety glove when working around CRTs due to the High Voltage present there.
15.Slide the ILA® /Relay Lens/CRT Assembly back and remove the ILA® assembly (it will slide out with some resistance).
16.There are two adjustment screws at the bottom of the ILA® assembly that move the ILA® up or down. Turn these screws in or out very slightly to allow the ILA® to seat lower or higher, as necessary.
17.Reinstall the ILA® assembly, slide the ILA® /Relay Lens/CRT Assembly forward and replace the spring clip.
18.Repeat Step 4 as necessary.
Model 250 Service Manual |