Chapter 8---Software and Protocol
Boot Manager Ver y.y.0 (Service Mode Startup)
Copyright (c)
Command: _
12A. To update the System Software from the Boot Manager prompt:
12B. Type in the command “loadsys” at the prompt. The following should be displayed:
Command: loadsys
System software update procedure
***WARNING: IMPROPER USE MAY MAKE THIS
SYSTEM UNBOOTABLE*** (NOTE: This warning relates to the Flash Memory updating that occurs in Step 12D below. Do not turn projector power
off while the | Flash | Memory is | updating.) |
Memory buffer | reset | to Oxff |
|
Begin your
12C. Select “Transfers/Send Text File” from the Windows Terminal Menu (normally in Accessories window). In the “Send Text File Dialog” box, select “List Files of Type: All Files” and select the disk and/or directory with the Model 250 software. Select file named “zsys.hex”. Press OK to start upload. Uploading takes about 20 minutes (9600 bps)
12D. During upload, a progress indicator updates the number of records received. When the upload is complete, the system will display the following (numerical values are for example only and depend on the System Software version):
Upload Successful
Address Range:
Bytes Loaded:360912
***WARNING: FLASH WILL NOW BE UPDATED***
Press Enter to continue, Esc to abort
12E. At this point the system has verified that the load module is correct and is ready to update the Flash memory. Press Enter to perform the update (Esc will abort the update process with no changes). While the Flash is being updated (approx.
Reprogramming Flash Sector 2 3 4 5 6 7 8 9
System software update successful
Command: _
Model 250 Service Manual |