Chapter 7---Troubleshooting
7.4 Error Codes
For certain errors that may occur in the Model 250 Projector the software provides error codes that are helpful in determining the nature of the problem. These error codes can be seen on the left side of the monitor screen when using a PC connected to Port A or Port B.
Table
Category | Error Category | Description | |
Number | |||
|
| ||
|
|
| |
1 | CEXEC | Operating System. | |
|
|
| |
2 | FLASH HW | Flash Memory HW driver. | |
|
|
| |
3 | IIC HANDLER | IIC Handler for Convergence/Deflection PCB, | |
|
| Horizontal/Vertical Deflection PCB, Raster | |
|
| Timing Generator PCB, Video Amplifier PCB, | |
|
| Video Processor PCB. | |
|
|
| |
4 | POWER ON/OFF | Power On Sequencing. | |
|
|
| |
5 | FLASH MANAGER | Flash Memory Data Manager. | |
|
|
| |
6 | VIDEO SWITCHER | EXTRON or JVC Video Switcher Handler. | |
|
|
| |
7 | ANSI OUTPUT | ANSI Output Display process. | |
|
|
| |
8 | UI CHAN/SRC | User Interface VIC Configuration Handler for | |
|
| Channel/SRC Data. | |
|
|
| |
9 | VIDEO INPUT CARD | VIC Card Handler. | |
|
|
| |
10 | HARDWARE | Misc HW (shutters, etc.). | |
|
|
| |
|
|
|
The error codes listed in Table
Table
Error | Description | ||
Number | |||
|
| ||
|
|
| |
1.5 | “Invalid read/wrt” | Software | |
|
| or Read command. | |
|
|
| |
1.12 | “Ser parity error” | Serial Port Parity | |
|
|
| |
1.13 | “Bad dev I/O oper” | Software | |
|
|
| |
1.27 | “Timeout on Read” | Software | |
|
|
|
Model 250 Service Manual |