![](/images/new-backgrounds/1269202/269202301x1.webp)
Chapter 7---Troubleshooting
to the Arc Lamp Power Supply low. The Arc Lamp Power Supply delivers 170 V to the Igniter, which generates a 32 kV pulse to the Arc Lamp and the Arc Lamp lights. Once the Arc Lamp lights, the Arc Lamp Power Supply, the /LAMP_LIT signal goes low and the voltage to the Igniter drops to between 25 V and 31 V. The voltage from the Arc Lamp Power Supply stays at a steady output of 2 kW during normal operation of the projector.
When the projector receives a power OFF command, the /LAMP_LIT and the /LAMP_ENA signal both go high. This shuts off the Arc Lamp Power Supply. The /FAN_ENA signal stays low for an additional ten minutes allowing the cooling fans to cool down the Arc Lamp, the Light Pipe and the PCBs. After ten minutes, the /FAN_ENA signal goes high, shutting off the cooling fans.
Model 250 Service Manual |