JVC 250 service manual ALPS - Service Adjustments, ALPS - Remove and Replace

Models: 250

1 190
Download 190 pages 59.74 Kb
Page 24
Image 24
ALPS - Service Adjustments

Chapter 3---Electrical

The Arc Lamp Power Supply sends the

/LAMP_LIT signal back to the System Controller when the Arc Lamp is lit.

The Arc Lamp regulates its output to give a constant Arc Lamp power. If the Arc Lamp has not lit within 20 seconds (/LAMP_LIT still high), the System Controller PCB will try once more to re-initiate the sequence. If the Arc Lamp still fails to light, an error code will appear on the back panel (see section 7.22 Error Codes).

The Arc Lamp Power Supply negative output goes to the Cathode of the Arc Lamp. The positive output goes to the Anode of the Arc Lamp and is tied to chassis ground.

The Arc Lamp Power Supply is shielded electrically and magnetically to prevent noise or disturbances in the CRTs or other circuitry.

Figure 3-3Arc Lamp Power Supply connections.

ALPS - Service Adjustments

The Arc Lamp Power Supply for the Model 250 is preset at the factory and does not have any Service Adjustments. The output is programmed for a constant

2 kW. Arc Lamp replacement does not require any electrical readjustments.

ALPS - Remove and Replace

Tools Needed

#2 Pozi-drive Phillips-head screwdriver

Parts Needed

Arc Lamp Power Supply p/n - 105216

To remove the Arc Lamp Power Supply (ALPS):

1.Power off the projector by IR Remote or PC, and allow the cooling fans to run until they shut off.

3-8

Model 250 Service Manual

Page 24
Image 24
JVC 250 service manual ALPS - Service Adjustments, ALPS - Remove and Replace