The Arc Lamp Power Supply sends the
/LAMP_LIT signal back to the System Controller when the Arc Lamp is lit.
The Arc Lamp regulates its output to give a constant Arc Lamp power. If the Arc Lamp has not lit within 20 seconds (/LAMP_LIT still high), the System Controller PCB will try once more to
The Arc Lamp Power Supply negative output goes to the Cathode of the Arc Lamp. The positive output goes to the Anode of the Arc Lamp and is tied to chassis ground.
The Arc Lamp Power Supply is shielded electrically and magnetically to prevent noise or disturbances in the CRTs or other circuitry.
Figure 3-3 Arc Lamp Power Supply connections.
ALPS - Service Adjustments
The Arc Lamp Power Supply for the Model 250 is preset at the factory and does not have any Service Adjustments. The output is programmed for a constant
2 kW. Arc Lamp replacement does not require any electrical readjustments.
ALPS - Remove and Replace
Tools Needed
#2
Parts Needed
Arc Lamp Power Supply p/n - 105216
To remove the Arc Lamp Power Supply (ALPS):
1.Power off the projector by IR Remote or PC, and allow the cooling fans to run until they shut off.
Model 250 Service Manual |