4.0 Optical

Chapter 4---Optical

4.0 Optical

Contents

4.1

Arc Lamp

4-2

4.2

Optical Path

4-7

4.3

ILA®

4-13

4.4

Relay Lenses

4-20

4.5

Projection Lens

4-20

Manual background CAUTION! Before performing procedures in this chapter, review the chapter on Safety at the beginning of this manual.

Manual background WARNING!!! When performing procedures in this chapter that require projector covers to be off, wear high voltage gloves (ANSI/ASTM 10,000 volt rated) when working near the CRTs, Arc Lamp, or power supplies. Wear safety goggles (rated X5) when working anywhere near the light path from the arc lamp or the projection lens.

Dangerous levels of ultraviolet and infrared radiation, dangerous glare, very high temperatures (180°C to 300°C) and high internal gas pressure are present at the Xenon Arc Lamp. The lamp is contained in a protective reflector-housing module and should not be operated outside this housing or outside of the projector.

When replacing the Arc Lamp, replace it as an entire module, as shown in this manual. Do not open the lamp housing or attempt to replace the Arc Lamp inside its module! Do not touch the Arc Lamp, or any connections, when the lamp is ignited or is arcing.

Any servicing of the Arc Lamp must remain restricted to Hughes-JVC Certified Technicians.