JVC 250 service manual Disconnect P45 “Control” at upper left of HVPS

Models: 250

1 190
Download 190 pages 59.74 Kb
Page 30
Image 30
10.Disconnect P45 (“Control”) at upper left of HVPS.

Chapter 3---Electrical

10.Disconnect P45 (“Control”) at upper left of HVPS.

11.Disconnect and label the three Focus cables. The square tabs on these cables (see Figure 3-6) may have to be lifted up. Gently pry up with a small Flathead screwdriver.

12.Remove all the cables from the slot in the cable guide located on the left side of the HVPS.

13.Verify that all plugs and cables are removed and out of the way so the HVPS is free to be removed.

14.Loosen (do not remove) the two Posi-drive screws (at the bottom of the HVPS) that secure the HVPS metal housing to the projector.

15.Remove the two Posi-drive screws that hold the top of the HVPS metal housing to the projector frame.

16.Grasp the HVPS at the bottom and lift upward and outward so that it slides away from the bottom screws.

17.Reinstall the High Voltage Power Supply in the reverse order.

NOTE: When reinstalling the High Voltage Power Supply:

!Make sure it slides over the bottom screws and the lip at the top of the projector frame.

!Make sure each anode cable “snaps” back into its receptacle. The receptacles are about 2” inside the hole where the cable goes.

!Make sure the rear flap on each focus cable connector snaps over the square socket securely. Wiggle the connector a little to make it fits securely.

18.Replace the HVPS cover.

19.Replace the projector covers.

20.After replacing the HVPS, check and adjust Electronic Focus as necessary.