JVC 250 service manual System Controller PCB - Outputs

Models: 250

1 190
Download 190 pages 59.74 Kb
Page 62
Image 62
System Controller PCB - Outputs

Chapter 5---Electronics

280_CLK - Square wave signal from the Raster Timing Generator PCB, with

50% duty cycle, synchronized to the horizontal sync at 280 times the frequency of the horizontal sync. This signal is used by the System Controller PCB to properly output shading and convergence data.

SOURCE_VALID - Signal from Raster Timing Generator PCB indicates a new source (or valid source). A high indicates a valid stable signal and a low indicates a change in input signal.

H_DRIVE - Square wave signal from Raster Timing Generator PCB, with a 50% duty cycle synchronized to the selected horizontal sync.

V_DRIVE - Square wave from Raster Timing Generator PCB, with a negative going pulse synchronized to selected vertical sync with a pulse width of about four horizontal lines.

/FRONT_IR - command signals from the front infrared receiver.

/REAR_IR - command signals from the rear infrared receiver

H_F2V - DC voltage from the Raster Timing Generator PCB, proportional to the horizontal frequency of the current source.

IIC CLK - IIC clock line, unidirectional clock line for control of synchronous data transfer of data between PCBs.

IIC DATA - IIC data line, bi-directional serial data line for control of synchronous data transfer between the System Controller PCB and the Raster Timing Generator PCB.

+5.1 V Stdby - from the Low Voltage Power Supply when the AC Circuit Breaker is turned on; it supplies power to the CPU, Interlock Switches, and IR Detectors before the projector receives the POWER ON command.

+5.1 V - from the Low Voltage Power Supply for all digital circuitry.

±15 V - from the Low Voltage Power Supply for all analog circuitry

GND - Ground

System Controller PCB - Outputs

/LV_ENA - signal to enable the Low Voltage Power Supply non-standby voltages after the System Controller PCB receives the POWER ON command.

/FAN_ENA - signal to the Low Voltage Power Supply to turn on the +24 V stby supply to turn on the cooling fans.

/LAMP_ENA - signal to enable the Arc Lamp Power Supply.

RGB_OVER - signal to Video Processor PCB for the On-screen Menu and /or Internal Test Pattern for red, green, and blue.

OVERLAY - signal to the Video Processor PCB, to switch between internal and external sources.

Model 250 Service Manual

5-7

Page 62
Image 62
JVC 250 service manual System Controller PCB - Outputs