Figure 4-7Optical Path

Chapter 4---Optical

Figure 4-7Optical Path

Optical Path - Service Adjustments

Tools Needed

3-mm Hex wrench

Parts Needed

No serviceable parts

The one adjustment that can be performed on the optical path is with the XY Positioner that moves the #1 Condensing Lens in the X- and Y-axis. The XY