TROUBLESHOOTING & REPAIR | ||||
|
|
|
|
|
POWER FEED 10M |
|
|
|
|
Observe Safety Guidelines detailed in the beginning of this manual. |
| |||
|
|
|
|
|
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
|
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
|
|
|
| FUNCTION PROBLEMS (Continued) |
| ||
|
|
| ||
The wire feed speed is consistent | 1. The DIP switch on the wire drive | 1. The feed head control board may | ||
and adjustable, but runs at the | unit may not be set for the cor- | be faulty. |
| |
wrong speed. |
| rect gear ratio. See the |
|
|
|
| Installation section of this man- |
|
|
|
| ual. |
|
|
|
|
|
| |
The unit shuts off while welding or | 1. The shut down circuit in the wire | 1. Disconnect any shutdown |
| |
attempting to weld. The STATUS | drive unit may be electrically | device from leads #570A and |
| |
LED is alternating between red | “open”. Make sure leads 570A | #570B (0.25 in. insulated tab |
| |
and green every second. The unit | & 570B are connected together. | terminals). Connect leads |
| |
tries to recover after 30 seconds |
| #570A and #570B together. If |
| |
and may repeat sequence. |
| 2. The drive motor may be over- | the feeder STATUS LED is now | |
|
| loaded due to a mechanical | steady green, the problem is in | |
|
| restriction in the wire feeding | the external shutdown circuit. |
|
|
| path. See Operation section of |
|
|
|
| this manual. | 2. If there are no restrictions in the | |
|
|
| wire feeding path, the drive |
|
|
|
| motor or gear box may be faulty. | |
|
|
| 3. The feed head control board |
|
|
|
| may be faulty. |
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department at