Lincoln Electric SVM172-A service manual Err 020, Err 100, Err 200, Err 201, Err 210

Models: SVM172-A

1 151
Download 151 pages 13.02 Kb
Page 116
Image 116

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-12

TROUBLESHOOTING & REPAIR

F-12

 

 

 

Observe all Safety Guidelines detailed throughout this manual Error Codes for the Power Wave 455: Code 10555 and below

Note: For any Err # listed below write down the error number for reference and try cycling power to see if the error clears itself. If not, refer to the What to Do column for the given Err.

 

PROBLEMS

POSSIBLE CAUSE

RECOMMENDED

 

(SYMPTOMS)

COURSE OF ACTION

 

 

 

 

 

Display shows any of the following:

 

 

 

 

 

 

Err

020

An attempt was made to reprogram

Check for potential electrical HF

 

 

a CB or feed head but the program

noise generators in the area. Try

 

 

did not verify.

removing the noise source and pro-

 

 

 

gramming again. If the Err 020 still

 

 

 

occurs, either replace the EEPROM

 

 

 

chip(s) in the board being repro-

 

 

 

grammed or replace the whole PC

 

 

 

board being reprogrammed.

 

 

 

 

Err

100

The Power Source issued a shut

See what to Do on Err 006.

 

 

down command for some reason.

 

 

 

 

 

Err

200

No Heart beat response from the

See what to Do on Err 006.

 

 

PS.

 

 

 

 

 

Err

201

No heart beat response from an

If this occurs while welding, the sta-

 

 

object.

tus LED should be flashing red on

 

 

 

the object that lost heart beat.

 

 

 

Otherwise, look for any nodes that

 

 

 

are flashing green. This indicates

 

 

 

they have not been recognized and

 

 

 

there is a power source problem

 

 

 

(see power source trouble shooting

 

 

 

section). If the status LED is either

 

 

 

flashing or solid red, there may be a

 

 

 

problem with continuity in the com-

 

 

 

munication lines. Check the lines for

 

 

 

continuity, in the cable and harness-

 

 

 

ing (refer to wiring diagram).

 

 

 

 

Err

210

EEPROM error.

Parameter recalled at power up was

 

 

 

out of range. Rotate Encoder Knob

 

 

 

to reset. Check all settings before

 

 

 

proceeding to weld. If this condition

 

 

 

persists then replace the CB mother

 

 

 

PC board.

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department at 1-888-935-3877 for electrical troubleshooting assistance before you proceed.

POWER FEED 10M SINGLE/DUAL

Page 116
Image 116
Lincoln Electric SVM172-A service manual Err 020, Err 100, Err 200, Err 201, Err 210