F-9

TROUBLESHOOTING & REPAIR

F-9

 

 

 

 

 

 

 

POWERFEED 10M

 

 

 

 

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS (Continued)

 

 

When the gun trigger is activated,

1. Check plug J83 on the wire

1. Perform the Drive Motor Test.

 

the drive rolls do not turn. The arc

drive control board, and leads

 

 

 

voltage is present and the solenoid

#550 and #551 for loose or

 

 

 

is energized. The STATUS LEDs

faulty conections. See wiring

2. The feedhead control board may

 

are steady green.

 

diagram.

be faulty.

 

 

 

 

 

 

 

The wire is feeding rough or not

1. The drive roll pressure may be

1. Contact the Lincoln Electric

 

 

feeding, but the drive rolls are turn-

incorrect. Set drive roll pres-

Service Department at

 

 

ing.

 

sure. See Operation section of

1.888.935.3877

 

 

 

 

this manual.

 

 

 

 

 

2. Check for dirty or rusty electrode

 

 

 

 

 

wire.

 

 

 

 

 

3. Make sure the drive rolls and

 

 

 

 

 

wire guides are positioned and

 

 

 

 

 

installed correctly. See

 

 

 

 

 

Operation section of this manu-

 

 

 

 

 

al.

 

 

 

 

 

4. Check for mechanical restric-

 

 

 

 

 

tions in the wire feeding path.

 

 

 

 

 

 

 

 

 

When in CC modes with the

 

1. Rotate Volts/Trim encoder knob

 

 

 

optional “MX” or “MXP” panels, the

at least 45 degrees clockwise.

1. Check option panel installation

 

otput does not energize.

 

This is normal. See

 

 

for loose of faulty connections.

 

 

 

Accessories section for detailed

 

 

 

 

 

 

 

 

operation.

 

 

 

 

 

 

 

 