Lincoln Electric SVM172-A service manual Step / 4 Step Operation

Models: SVM172-A

1 151
Download 151 pages 13.02 Kb
Page 82
Image 82

BB-14

OPERATION

BB-14

 

 

 

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Recalling from Memory

To recall the contents of a memory into the active proce- dure, momentarily push the desired memory button (for less than 2 seconds). The saved parameters will be copied into the active procedure, and the LED of the memory button will light indicating the source of the infor- mation. As with saving to memory, this light will remain lit as long as the contents of the source memory remain equal to the contents of the associated procedure.

If a constant current mode is saved to memory with the power source in the "on" state, the "on" status will be changed to "off" when the procedure is recalled. This pre- vents a potential safety hazard if a memory button is pushed and the power source unexpectedly turns on.

2 STEP / 4 STEP OPERATION

The Wire Drive has a 2 Step / 4 Step switch located near the gun connector. 2-Step Trigger Mode operation requires the operator hold the gun trigger closed in order to weld. 4-Step Trigger Mode eliminates the need to hold the gun trigger closed while welding. User- selectable 4-step modes with or without current inter- lock. The switch in the down position will enable 2-Step operation and in the up position enables 4 -Step oper- ation. This switch has no effect in CC modes of opera- tion, such as stick welding. Both 2 and 4 -Step can be operated in Synergic and Non-Synergic modes. In a Synergic mode, machine output tracks Wire Feed Speed (WFS) during welding. In Non-Synergic modes, machine output is independent of WFS.

2 Step Synergic Operation:

Without Start/Crater/Burnback functions active

Waveform Sequence:

1.Trigger is pulled; Preflow sequence begins and runs until preflow timer expires.

2.Strike sequence initiates until Arc is established.

3.Arc established; Weld sequence begins.

4.Trigger released (Arc extinguished); Postflow sequence begins and runs until postflow timer expires.

5.End of sequence.

2 Step Synergic Operation: With Burnback function active.

Waveform Sequence:

1.Trigger is pulled; Preflow sequence begins and runs until preflow timer expires.

2.Run-In sequence initiates until Arc is established.

3.Arc established; Weld sequence begins.

4.Trigger released (Arc extinguished); Burnback sequence begins and runs until burnback timer expires.

5.Postflow sequence begins and runs until postflow timer expires.

6.End of sequence.

1

2

3

4

5

6

WFS vs. Work point (Output) Waveform

= solid line represents WFS

---= dashed line represents Work point or Machine Output

2 Step Synergic Operation:

With Start/Crater/Burnback functions active.

Waveform Sequence:

1.Trigger is pulled; Preflow sequence begins and runs until preflow timer expires.

2.Run-In sequence initiates until Arc is established.

3.Arc established; Start sequence begins and runs for the amount of time set.

4.Weld sequence begins.

5.Trigger released; Crater sequence begins and runs until crater timer expires.

6.Arc Extinguished; Burnback sequence begins and runs until burnback timer expires.

7.Postflow sequence begins and runs until postflow timer expires.

8.End of process.

Return to Section TOC

Return to Master TOC

1

2

3

4

5

6

7

8

1

2

3

4

5

WFS vs. Work point (Output) Waveform

= solid line represents WFS

WFS vs. Work point Waveform---= dashed line represents Work point or Machine Output = solid line represents WFS

---= dashed line represents Work point or Machine Output

POWER FEED 10M SINGLE/DUAL