TROUBLESHOOTING & REPAIR | ||||
|
|
|
| |
POWER FEED 10M |
|
|
| |
| Observe Safety Guidelines detailed in the beginning of this manual. |
| ||
|
|
|
| |
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED | |
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION | |
|
|
|
|
|
| FUNCTION PROBLEMS (Continued) |
| ||
|
|
| ||
The displays are blank (not lit). | 1. Check for loose or faulty connec- | 1. Check for 5VDC at J37 pins 2 | ||
The wire feeds when the gun trig- | tions at plug on the display | and 10 on the display board. If 5 | ||
ger is activated. |
| board, to plug on the feedhead | VDC is present, then the display | |
|
| control board. | board may be faulty. | |
|
|
| 2. If the 5VDC is low or not present, | |
|
|
| check for loose or faulty connec- | |
|
|
| tions in SPI circuit. See machine | |
|
|
| schematic. |
|
|
|
| 3. The feedhead control board ma | |
|
|
| be faulty. |
|
|
|
| ||
The dual procedure is not function- | 1. Make certain the LED indicator | 1. Check sheilded cable lead and | ||
al when using the remote Dual | on the Dual Procedure Panel is | connections from J86 on PC BD | ||
Procedure switch. | The STATUS | in the middle position. This | to MSP panel. Check SPI cable | |
LEDs are steady green on the | enables the gun remote dual pro- | from MSP panel to Dual/memory | ||
power source, Control Box and wire | cedure switch. | panel. Per machine schematic. | ||
drive units. |
|
|
|
|
|
|
| 2. Check for 5VDC at J86 pins 2 | |
|
|
| and 10. Check for 15VDC at J86 | |
|
|
| pins 1 and 10. If voltage is not | |
|
|
| present replace feed head or | |
|
|
| user interface BD depending on | |
|
|
| model. If leads and voltages are | |
|
|
| good replace | dual/memory |
|
|
| panel. |
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department at