Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
| NOTES | ||||
|
|
|
|
| |
P.8 | TIG Gas Control (Two Settings) | P.13 | Adjust Arc Force | ||
| 1. | "Valve (manual)", the internal solenoid will not |
| Use this menu to adjust Arc Force values for Start, | |
|
| actuate while TIG welding, gas flow is manually |
| Weld and Crater. Press the right MSP4 button to | |
|
| controlled by an external valve. |
| enter the menu and rotate the knob to choose either | |
| 2. | "Solenoid (auto)", the internal gas solenoid will |
| Start, Weld or Crater. Press the right MSP4 button | |
|
| turn on and off automatically while TIG welding |
| and then rotate the knob to the desired value. | |
|
| as follows: |
| Press the left MSP4 button to set the value and exit. |
•Preflow time will not be accessible from the MSP4.
•Postflow time will be available in the MSP4 "End
| Options" and have a range of OFF to 10.0 sec- |
| Continue to adjust Arc Force for other states, and | |
| onds. |
|
| then press the left MSP4 button to exit the menu. |
| • The postflow time value is maintained when |
|
| |
| switching between MIG and TIG modes. | P.80 | Sense From Studs (two settings) | |
| • When machine output on/off is controlled via the |
| 1. "False", the voltage sense lead is automatically | |
| right encoder, gas flow will not start until the tung- |
| selected based on the DIP switch configuration | |
| sten touches, the work piece, gas flow will stop |
| and the selected weld mode. This is the default | |
| after the postflow time when the arc is broken. |
| value that is used every time the machine is pow- | |
| • When machine output on/off is controlled via an |
| ered up. Note that setting P.80 to "False" does | |
| arc start switch or foot Amptrol, gas will begin flow- |
| not preclude voltage sensing from the studs if | |
| ing when the output is turned on and stop flowing |
| studs sensing is specified by the selected weld | |
| after the postflow period after the output is turned |
| mode (for example stick and TIG weld modes will | |
| off. |
|
| still sense voltage at the studs). |
P.9 | Crater Delay |
|
| 2. "True", voltage sensing is forced to "studs" |
| This parameter enables a timer delay for each feed |
| regardless of the DIP switch configuration and | |
| head to bypass the Crater option when short tack |
| selected weld mode. Setting P.80 to "True" | |
| welds are desired. If the trigger is released before |
| should only be done for troubleshooting purpos- | |
| the timer expires, Crater will be bypassed and the |
| es. P.80 will automatically be set back to "False" | |
| weld will end. If the trigger is released after the timer |
| the next time the equipment is powered up or can | |
| expires, Crater will function as normal (if Crater |
| be manually changed back to "False" via the | |
| function is turned on). |
|
| setup menu. |
P.11 | Set Timers |
|
| In order to control the welding arc, the power source |
| This menu is used to adjust timer values for |
| continually monitors arc current and arc voltage. | |
| Upslope, Downslope and Restrike. Press the right |
| Arc current is measured internal to the power | |
| button to enter the Set Timer menu. Rotate the |
| source. Arc voltage can be measured as follows: | |
| knob to select the timer to adjust and then press the |
| • Voltage internal to the power source ("studs") | |
| right button. Adjust the value of the timer by rotating |
| • Voltage at the wire feeder ("67" lead) | |
| the knob. Press the left MSP4 button to set the |
| • Voltage at a | |
| value and exit. Continue to adjust other timers as |
|
| |
| necessary, and then press the left button to exit the |
| Remote voltage sensing (anything other than | |
| Set Timer menu. |
|
| "studs") is used to obtain a more accurate voltage |
|
|
|
| measurement since the sense lead is closer to the |
P.12 | Travel Options |
|
| arc. Remote voltage sensing can involve external |
| This menu is used to change the travel options for a |
| wiring and DIP switch configuration, there is a | |
| travel carriage, including starting and ending func- |
| potential for incorrect voltage measurement which | |
| tions. The right MSP4 button to enter the Travel |
| can lead to poor arc control or wire burn back. | |
| Options menu and rotate the encoder to select |
|
| |
| either starting or ending options. | Press the right | P.99 | Show Test Modes |
| MSP4 button to select the option. | Press the left |
| Many weld tables include special modes for testing |
| MSP4 button to set the value and exit. Rotate the |
| and servicing the welding system. Set this parame- | |
| encoder to select other options, or press the left |
| ter to YES to show all test modes. | |
| MSP4 button to exit the menu. |
|
|
|
|
|
|
| When the power source is turned off, the Show Test |
|
|
|
| Modes parameter automatically reverts back to |
|
|
|
| "NO". |
POWER FEED 10M SINGLE/DUAL