| OPERATION | |||||
2 STEP TRIGGER OPERATION |
|
| 3. UPSLOPE: Once the wire touches the work and an | ||||
(See Figure B.4) |
|
|
|
| |||
|
|
|
| arc is established, both the machine output and the | |||
Sometimes it is advantageous to set specific arc start, | |||||||
wire feed speed ramp to the weld settings through- | |||||||
crater and arc ending parameters for the ideal weld. | |||||||
out the start time. The time period of ramping from | |||||||
Many times when welding aluminum crater control is | |||||||
the start settings to the weld settings is called UPS- | |||||||
necessary to make a good weld. This is done by set- | |||||||
LOPE. |
| ||||||
ting Start, Crater and Burnback functions to desired |
| ||||||
|
| ||||||
values. |
|
|
|
| 4. WELD: After upslope, the power source output and | ||
|
|
|
|
| |||
SEQUENCE OF OPERATION |
|
|
| the wire feed speed continue at the weld settings. | |||
|
|
|
|
| |||
Following is the total weld sequence that the Power | 5. CRATER: As soon as the trigger is released, the | ||||||
wire feed speed and power source output ramp to | |||||||
Feed 10M Single Wire Feeder will execute. If any para- | |||||||
the crater settings throughout the crater time. The | |||||||
meter is inactive or its time is set to zero, the weld pro- | |||||||
time period of ramping from the weld settings to the | |||||||
cedure immediately shifts to the next parameter in the | |||||||
crater settings is called DOWNSLOPE. |
| ||||||
sequence. |
|
|
|
|
| ||
|
|
|
|
|
| ||
1. PREFLOW: Shielding gas begins to flow immediate- | 6. BURNBACK: After the crater time expires, the wire | ||||||
feed speed is turned OFF and the machine output | |||||||
ly when the gun trigger is pulled. |
|
| |||||
|
| continues for the burnback time. |
| ||||
|
|
|
|
|
| ||
2. STRIKE: After preflow | time | expires, | the | power | 7. POSTFLOW: Next, the machine output is turned | ||
source regulates to the | start | output | and | wire is | |||
|
|
advanced towards the work piece at the Strike WFS. | OFF and shielding gas continues until the post flow | |
timer expires. | ||
If an arc is not established within 1.5 seconds, the | ||
| ||
power source output and wire feed speed skips to |
| |
the weld settings. |
|
FIGURE B.4
| Head / Procedure Select |
| Memory |
• | Press to select head or change active | • | Permanent storage for procedure |
| procedure. |
| settings. |
• | Changes to weld settings affect | • | Six available memory locations. One |
| active procedure only. |
| procedure (A or B) can be stored in |
| t |
| each. |
MEMORY |
PRESS AND HOLD TO SAVE
POWER FEED 10M SINGLE/DUAL