Lincoln Electric SVM172-A Step Trigger Operation, See Figure B.4, Sequence of Operation

Models: SVM172-A

1 151
Download 151 pages 13.02 Kb
Page 36
Image 36

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

B-14

 

 

OPERATION

B-14

2 STEP TRIGGER OPERATION

 

 

3. UPSLOPE: Once the wire touches the work and an

(See Figure B.4)

 

 

 

 

 

 

 

 

arc is established, both the machine output and the

Sometimes it is advantageous to set specific arc start,

wire feed speed ramp to the weld settings through-

crater and arc ending parameters for the ideal weld.

out the start time. The time period of ramping from

Many times when welding aluminum crater control is

the start settings to the weld settings is called UPS-

necessary to make a good weld. This is done by set-

LOPE.

 

ting Start, Crater and Burnback functions to desired

 

 

 

values.

 

 

 

 

4. WELD: After upslope, the power source output and

 

 

 

 

 

SEQUENCE OF OPERATION

 

 

 

the wire feed speed continue at the weld settings.

 

 

 

 

 

Following is the total weld sequence that the Power

5. CRATER: As soon as the trigger is released, the

wire feed speed and power source output ramp to

Feed 10M Single Wire Feeder will execute. If any para-

the crater settings throughout the crater time. The

meter is inactive or its time is set to zero, the weld pro-

time period of ramping from the weld settings to the

cedure immediately shifts to the next parameter in the

crater settings is called DOWNSLOPE.

 

sequence.

 

 

 

 

 

 

 

 

 

 

 

1. PREFLOW: Shielding gas begins to flow immediate-

6. BURNBACK: After the crater time expires, the wire

feed speed is turned OFF and the machine output

ly when the gun trigger is pulled.

 

 

 

 

continues for the burnback time.

 

 

 

 

 

 

 

2. STRIKE: After preflow

time

expires,

the

power

7. POSTFLOW: Next, the machine output is turned

source regulates to the

start

output

and

wire is

 

 

advanced towards the work piece at the Strike WFS.

OFF and shielding gas continues until the post flow

timer expires.

If an arc is not established within 1.5 seconds, the

 

power source output and wire feed speed skips to

 

the weld settings.

 

FIGURE B.4

 

Head / Procedure Select

 

Memory

Press to select head or change active

Permanent storage for procedure

 

procedure.

 

settings.

Changes to weld settings affect

Six available memory locations. One

 

active procedure only.

 

procedure (A or B) can be stored in

 

t

 

each.

MEMORY

PRESS AND HOLD TO SAVE

POWER FEED 10M SINGLE/DUAL

Page 36
Image 36
Lincoln Electric SVM172-A service manual Step Trigger Operation, See Figure B.4, Sequence of Operation