DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids

Page8-382test processor

8
test processor

This command performs hardware diagnostic tests on a specified processor

circuit pack.
Defaults

For SPE simplex systems, the location is optional and defaults to cabinet 1,

carrier a. For SPE duplex systems, the cabinet default is again cabinet 1, but

there is no default for the carrier. Defaults for the remaining parameters are short

with a repeat of 1.

1. If no alarms are registered a gainst the maintenance objec t then the test sequence is ru n only once. The
long
clear
option forces a clear of all a la rms i f no e rro rs a r e encou nt e red d uri ng t esti ng . Th e
short clear
option only
clears alarms pertinent to tests in the short sequen ce.
2. Refer to the Report Scheduler an d System Printer feature specifica tion for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
test processor location
short
long
clear
schedule
Cabinet number (optional for
simplex) and carrier l etter (optional
a for simplex; a or b for duplex).
Option for a brief seri es of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of bo th
destructive and nondestructive
diagnostic tests.
This option causes the test
sequence (short or long) to repea t
until the alarm (if any) is clear ed or
a single test in the sequ ence fails.1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is th en
placed in the command qu eue and
is executed at the specified time.
The information displayed by the
command is sent to the syst em
printer instead of the sc reen.2
Examples:
test processor
test processor schedule
test processor a
test processor 1a
test processor b sh
test processor a l c
init
inads
craft
See
below none