Motorola MVME187 manual Table A-1. ENV Command Parameters Continued

Models: MVME187

1 173
Download 173 pages 29 Kb
Page 141
Image 141
Manual background

Setting Environment to Bug/Operating System

Table A-1. ENV Command Parameters (Continued)

ENV Parameter and Options

Default

Meaning of Default

 

 

 

F-Page (VMEbus A24) Enable

Y

Yes, Enable the F-Page Address

[Y/N]

 

Decoder.

 

 

 

F-Page (VMEbus A24) Control

02

Works the same as Slave Control #1.

 

 

Default is $02.

 

 

 

ROM Speed Bank A Code

05

Used to set up the ROM speed.

ROM Speed Bank B Code

05

Default is $05 = 165 ns (25 MHz

 

 

MVME187) or $04=145 ns (33 MHz

 

 

MVME187).

 

 

 

Static RAM Speed Code

01

Used to set up the SRAM speed.

 

 

Default is $01 = 125 ns (25 MHz

 

 

MVME187) or $00=115 ns (33 MHz

 

 

MVME187).

 

 

 

PCC2 Vector Base

05

Base interrupt vector for the

VMEC2 Vector Base #1

06

component speciÞed. Default:

VMEC2 Vector Base #2

07

PCCchip2 = $05, VMEchip2 Vector 1 =

 

 

$06, VMEchip2 Vector 2 = $07.

 

 

 

VMEC2 GCSR Group

CE

SpeciÞes the group address

Base Address

 

($FFFFXX00) in Short I/O for this

 

 

board. Default = $CE.

 

 

 

VMEC2 GCSR Board Base

00

SpeciÞes the base address

Address

 

($FFFFCEX0) in Short I/O for this

 

 

board. Default = $00.

 

 

 

VMEbus Global Time Out Code

01

This controls the VMEbus timeout

 

 

when this MVME187 is the system

 

 

controller. Default $01 = 64 s.

 

 

 

Local Bus Time Out Code

00

This controls the local bus timeout.

 

 

Default $00 = 8 s.

 

 

 

VMEbus Access Time Out Code

02

This controls the local bus to VMEbus

 

 

access timeout. Default $02 = 32 ms.

 

 

 

A-13