CNetwork Controller

Data

C

Network Controller Modules Supported

The VMEbus network controller modules supported by MVME187Bug are shown in Table C-1. The default address for each type and position is shown to indicate where the controller must reside to be supported by MVME187Bug.

The CLUNs and DLUNs are used in conjunction with the following debugger commands and debugger system calls:

Debugger Commands

Debugger System Calls

 

 

NBH

.NETRD

 

 

NBO

.NETWR

 

 

NIOC

.NETFOPN

 

 

NIOP

.NETFRD

 

 

NIOT

.NETCFIG

 

 

NPING

.NETCTRL

 

NAB

 

 

 

The controllers are accessed via the CLUNs and DLUNs specified in the following table.

Table C-1. Network Controller Access Data

Controller

CLUN

DLUN

Address

Interface

Type

 

 

 

Type

MVME187

$00

$00

$FFF46000

Ethernet

 

 

 

 

 

MVME376

$02

$00

$FFFF1200

Ethernet

 

 

 

 

 

MVME376

$03

$00

$FFFF1400

Ethernet

 

 

 

 

 

MVME376

$04

$00

$FFFF1600

Ethernet

 

 

 

 

 

MVME376

$05

$00

$FFFF5400

Ethernet

 

 

 

 

 

MVME376

$06

$00

$FFFF5600

Ethernet

 

 

 

 

 

C-1

Page 149
Image 149
Motorola MVME187 Network Controller Modules Supported, Table C-1. Network Controller Access Data, Address Interface, Type