SPRS292A − OCTOBER 2005 − REVISED NOVEMBER 2005

INPUT AND OUTPUT CLOCKS (CONTINUED)

switching characteristics over recommended operating conditions for CLKOUT2†‡ (see Figure 23)

 

 

 

GDPA-167

 

 

 

 

ZDPA−167

 

NO.

 

PARAMETER

−200

 

UNIT

 

 

 

−250

 

 

 

 

 

MIN

MAX

 

 

 

 

 

 

 

1

tc(CKO2)

Cycle time, CLKOUT2

C2 − 0.8

C2 + 0.8

ns

2

tw(CKO2H)

Pulse duration, CLKOUT2 high

(C2/2) − 0.8

(C2/2) + 0.8

ns

3

tw(CKO2L)

Pulse duration, CLKOUT2 low

(C2/2) − 0.8

(C2/2) + 0.8

ns

4

tt(CKO2)

Transition time, CLKOUT2

 

2

ns

The reference points for the rise and fall transitions are measured at VOL MAX and VOH MIN.

C2 = CLKOUT2 period in ns. CLKOUT2 period is determined by the PLL controller output SYSCLK2 period, which must be set to CPU period divide-by-2.

1

4

2

CLKOUT2

3

4

Figure 23. CLKOUT2 Timings

switching characteristics over recommended operating conditions for CLKOUT3†§ (see Figure 24)

 

 

 

GDPA-167

 

 

 

 

ZDPA−167

 

NO.

 

PARAMETER

−200

 

UNIT

 

 

 

−250

 

 

 

 

 

MIN

MAX

 

 

 

 

 

 

 

1

tc(CKO3)

Cycle time, CLKOUT3

C3 − 0.9

C3 + 0.9

ns

2

tw(CKO3H)

Pulse duration, CLKOUT3 high

(C3/2) − 0.9

(C3/2) + 0.9

ns

3

tw(CKO3L)

Pulse duration, CLKOUT3 low

(C3/2) − 0.9

(C3/2) + 0.9

ns

4

tt(CKO3)

Transition time, CLKOUT3

 

3

ns

5

td(CLKINH-CKO3V)

Delay time, CLKIN high to CLKOUT3 valid

1.5

7.5

ns

The reference points for the rise and fall transitions are measured at VOL MAX and VOH MIN.

C3 = CLKOUT3 period in ns. CLKOUT3 period is a divide-down of the CPU clock, configurable via the OSCDIV1 register. For more details, see

PLL and PLL controller.

CLKIN

CLKOUT3

1

3

2

5

5

4

4

NOTE A: For this example, the CLKOUT3 frequency is CLKIN divide-by-2.

Figure 24. CLKOUT3 Timings