SPRS292A − OCTOBER 2005 − REVISED NOVEMBER 2005

absolute maximum ratings over operating case temperature range (unless otherwise noted)

Supply voltage range, CVDD (see Note 2)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . − 0.3 V to 1.8

V

Supply voltage range, DVDD (see Note 2)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . −0.3 V to 4

V

Input voltage range

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to DV DD + 0.5 V

Output voltage range

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to DV DD + 0.5 V

Operating case temperature ranges, TC

(default)

. . . . . . 0_C to 90_C

 

(A version) [C6711DGDPA and C6711DZDPA]

. . . −40 _C to105_C

Storage temperature range, Tstg

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . −65 _C to 150_C

Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

NOTE 2: All voltage values are with respect to VSS.

recommended operating conditions

 

 

 

 

 

 

 

MIN

NOM

MAX

UNIT

 

 

 

 

 

 

 

 

 

 

 

CVDD

Supply voltage, Core

−250 only

1.33

1.4

1.47

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.14§

1.20§

1.32

V

DVDD

Supply voltage, I/O

 

 

 

 

 

3.13

3.3

3.47

V

VSS

Supply ground

 

 

 

 

 

0

0

0

V

VIH

High-level input voltage

All signals except CLKS1, DR1, and

RESET

 

2

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLKS1, DR1, and RESET

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All signals except CLKS1, DR1, and

 

 

 

 

0.8

 

VIL

Low-level input voltage

RESET

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLKS1, DR1, and RESET

 

 

0.3*DVDD

 

 

 

 

 

 

 

All signals except ECLKOUT, CLKOUT2, CLKS1, and

 

 

–8

 

IOH

High-level output current

DR1

 

 

mA

 

 

 

 

 

ECLKOUT and CLKOUT2

 

 

–16

 

 

 

 

 

 

 

 

 

 

All signals except ECLKOUT, CLKOUT2, CLKS1, and

 

 

8

mA

 

 

DR1

 

 

 

Low-level output current

 

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL

 

ECLKOUT and CLKOUT2

 

 

16

mA

 

 

 

 

 

 

CLKS1 and DR1

 

 

3

mA

 

 

 

 

 

 

 

 

 

 

 

TC

Operating case

Default

0

 

90

_C

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

Maximum voltage during overshoot (See Figure 19)

 

 

4#

V

OS

 

 

 

 

 

 

 

 

 

 

V

Maximum voltage during undershoot (See Figure 20)

 

 

−0.7 #

V

US

 

 

 

 

 

 

 

 

 

 

TC

Operating case

A version (C6711DGDPA and C6711DZDPA)

–40

 

105

_C

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The core supply should be powered up prior to (and powered down after), the I/O supply. Systems should be designed to ensure that neither supply is powered up for an extended period of time if the other supply is below the proper operating voltage.

§These values are compatible with existing 1.26−V designs.

Refers to DC (or steady state) currents only, actual switching currents are higher. For more details, see the device-specific IBIS models.

# The absolute maximum ratings should not be exceeded for more than 30% of the cycle period.

62

POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443

Page 62
Image 62
Motorola TMS320C6711D warranty Recommended operating conditions‡, MIN NOM MAX Unit, Ioh