DATA PROGRAMMING
Assignment of FCH Related Data
STEP 1: ANPDN/ANPDL Note
Assign the first digit of the LCR/LCRS access code. When the access code is common to all nodes, use the ANPDN command. When the access code is assigned for each node, use the ANPDL com- mand.
TN=1 | 1st DC=8 | CI=N (Normal) | NND=1 |
TN=1 | 1st DC=8 | CI=H (Hooking) | NND=1 |
STEP 2: ASPAN/ASPAL Note
Assign the LCR/LCRS access code for a dummy route number. When the access code is common to all nodes, use the ASPAN command. When the access code is assigned for each node, use the ASPAL command.
ACC=8 | CI=N (Normal) | SRV=LCR/LCRS | LGRT=Dummy route number |
ACC=8 | CI=H (Hooking) | SRV=LCR/LCRS | LGRT=Dummy route number |
STEP 3: AMND |
|
|
|
Using AMND, assign the Maximum Necessary Digits to be received by Register (ORT) circuit.
DC=8110 MND=8
STEP 4: ARNPL
Using ARNPL, assign the access code for each external trunk route, but not for a dummy route.
RT=10 ACC=8
RT=200 ACC=9
Note: When entering the data in STEP 1, 2, 6, 7 and 8, do not mix the commands for LDM and NDM. Write the data on the same data memory as shown below:
•When writing the data on the LDM:
ANPDL → | ASPAL → | AFRSL → | AOPRL → | AADCL |
(STEP 1) | (STEP 2) | (STEP 6) | (STEP 7) | (STEP8) |
•When writing the data on the NDM:
ANPDN → | ASPAN → | AFRSN → | AOPRN → | AADCN |
(STEP 1) | (STEP 2) | (STEP 6) | (STEP 7) | (STEP8) |
ND-70185 (E)CHAPTER 5
Page 91
Revision 3.0