EX- FCCS
Data Programming
1.To Log-in to All Nodes in EX-FCCS Network
Perform the following data programming at each NCN of all the Fusion Groups.
STEP 1: AFUGN
Assign
STEP 2: AEXFN
Assign the CCH Selection Data by designating all the Fusion Point Code (FPC) and the Point Code (PC) in the connected Fusion Group.
Note: Confirm whether the Centralized MAT can log in to each node here. Reexamine the assigned data so far if log in can’t be executed. There may be some error in data setting.
2.To Access
Assign the data at the NCN of each Fusion Group. Abbreviate Digit Code (ADC) data must be set by AEADN command at each NCN of all the FUGs. Assign the
<NCN of each FUG>
AEADN: Assign the Abbreviate Digit Code (ADC) for connection Fusion Group. Enter the FUG Number as- signed by AFUGN command, TN, and ADC to be assigned.
<NCN of the Center FUG>
AELGN: Telephone Numbers must be assigned for all the station within the network uniquely. Use AELGN command to allocate
Only readout function can be used by this command in case both the Self FUG Number and the Con- nection FUG Number are assigned, if the Self FUG is not the Center FUG.
Note: Check whether the trunk originating call via CCIS can be executed by dialing
CHAPTER 8 |
Page 194
Revision 3.0