POST INSTALLATION TEST

FCCS Network Connection Test

3.43-party Conference Trunk Function Test (via FCCS)

Perform the 3-party conference trunk function test, following the procedures listed below.

STEP 1: Using the MBTK Command, make busy all 3-party Conference Trunk (CFTs) except the trunk to be tested.

Check

STEP 2: Establish a station-to-station connection between STNs A and B in self node (Node A).

STEP 3: STN A goes to Switch Hook Flash (SHF), and after hearing SPDT, dials the Telephone Number of STN C in other node (Node B).

STEP 4: STN C answers the call.

STEP 5: STN A, after a brief talk with STN C, makes a SHF, and confirms that a three-way connection has been set up.

STEP 6: Release the call.

STEP 7: Repeat the above steps for all CFTs.

STEP 8: Using the MBTK command, cancel the make-busy status of the trunk.

Node A (Self-Node)

 

Node B

SHF￿

 

 

+￿

RBT,￿

 

TELN: 420000

 

 

SPDT

 

LC

 

LC

STN A￿

FCCS

STN C￿

TELN: 410000￿

 

TELN: 420000￿

STN: 2000

 

STN: 2000

￿

 

RG

LC

C

 

 

 

STN B￿

F

 

TELN: 410001￿

T

 

STN: 2001

 

TSW / MUX Card

 

Figure 6-11 3-party Conference Trunk Function Test via FCCS

Note: When a station activates this feature, CFT in Self-Node is used. In this case, CFT in Node A is used.

3.5FCCS Alternate Routing Test

This section explains how to perform the test for Fusion-link alternate routing. Following the procedures below, make sure that the connection and alternate routing to all FCCS lines are normal and correctly es- tablished.

CHAPTER 6

ND-70185 (E)

Page 142

Revision 3.0

Page 157
Image 157
NEC NEAX2400 system manual party Conference Trunk Function Test via Fccs