INSTALLATION

Connecting Cables

When dual LANIs are used in both Slot 00 and 03 of CPR#0/CPR#1, be sure to use at least two HUB cards as separate 10 BASE-T connection terminals. Use one HUB for the internal LANI (LANI-A: in Slot 00 of each CPR) and use the other for the external LANI (LANI-B in Slot 03 of each CPR).

2.When the HUB is in a dual configuration, connect the 10 BASE-T cross cable between the HUB cards. Use the following cables, which are provided by the user.

UTP CTG5 CRS CA-F:When the HUB and HUB are in the same PIM

UTP CTG5 CRS CA-O:When the HUB and HUB are in different PIMs but in the same IMG UTP CTG5 CRS CA-X:When the HUB and HUB are in different IMG stacks

When using more than two HUB cards, also connect the cross cable(s) for the remaining HUB card(s), except the HUB for the MAT connection.

This step is not necessary when your system uses dual LANIs for CPU#0/CPU#1 and FCH is also in a dual configuration.

3.Connect the 10 BASE-T straight cable(s) between the HUB and FCH (PA-FCHA) cards. Use the following cable, which must be provided by the user.

UTP CTG5 ST CA-F: When the HUB and FCH are in the same PIM

UTP CTG5 ST CA-O: When the HUB and FCH are in different PIMs but in the same IMG

UTP CTG5 ST CA-X:When the HUB and FCH are in different IMG stacks

When FCH is in a dual configuration, connect FCH#0 to the HUB#0 side, and FCH#1 to the HUB#1 side.

4.3.5Procedure for IMX-U System

When your system is the IMX-U type (configured to a maximum of 4 Local Nodes + 1ISW), the pro- cedure for the 10 BASE-T connection is as follows. Because this system already has a Fusion Link via the HUB (PA-M96) cards, this section gives details related only to the connection between the HUB and FCH (PA-FCHA) cards.

1.Refer to the NEAX2400 IMX Installation Manual (IMX-U Type) to make sure that the necessary 10 BASE-T (both straight and cross) connections between the ISW and each LN (Local Node) are all securely provided.

2.Connect the 10 BASE-T straight cable(s) between the HUB (PA-M96) and FCH (PA-FCHA) cards. Use the following cable, which must be provided by the user.

UTP CTG5 ST CA-F: When the HUB and FCH are in the same PIM

UTP CTG5 ST CA-O:When the HUB and FCH are in different PIMs but in the same IMG UTP CTG5 ST CA-X:When the HUB and FCH are in different IMG stacks but in the same LN UTP CTG5 ST CA-A0:When the HUB and FCH are in different LNs