INSTALLATION

Connecting Cables

Figure 4-15shows some typical examples, where 10 BASE-T cables are connected to the FCH card(s) mounted in PIM2 of 1-IMG system, under the following conditions:

 

Configuration

Configuration

Used Cable Unit

 

Number of HUB/

 

of CPU

of LAN

(Note 1, Note 2)

 

 

 

FCH

 

 

 

 

 

 

 

 

 

 

Pattern 1

Single

Single

SR1201 ETIF CAU-C

1

 

HUB

1, FCH

1

 

 

 

 

 

 

 

 

 

Pattern 2

Dual

Single

SR1201 ETIF CAU-C

1

 

HUB

2, FCH

2

SR1201 ETIF CAU-DC

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pattern 3

Single

Dual

SR1201 ETIF CAU-C

2

 

HUB

2, FCH

2

 

 

 

 

 

 

 

 

 

Pattern 4

Dual

Dual

SR1201 ETIF CAU-C

2

 

HUB

2, FCH

2

SR1201 ETIF CAU-DC

2

 

 

 

 

 

 

Note 1: Cables contained in each cable unit are as follows.

SR1201 ETIF CAU-C: UTP CTG5 ST CA-M, UTP CTG5 ST CA-J

SR1201 ETIF CAU-DC: UTP CTG5 ST CA-K, UTP CTG5 ST CA-J, UTP CTG5 CRS CA-F

Note 2: The cables cited in Figure 4-15can be used in the 1-IMG system only. Refer to Page 45 through Page 48 for more details.

HUB (PA-M96) FCH (PA-FCHA)

ATTENTION

Connectors for 10 BASE-T

 

 

 

 

 

 

 

Contents

 

 

 

 

 

 

 

Static Sensitive

 

 

 

 

 

 

 

Handling

 

 

 

<FCH in PIM2 (Pattern 1)>

 

<FCH in PIM2 (Pattern 2)>

Precautions Required

CN

= 10 BASE-T Connector

 

 

 

 

 

 

 

Use 10 BASE-T connectors.

 

 

 

 

 

 

 

 

 

TOPU

 

 

TOPU

 

TP7-X

10 BASE-T

 

 

 

 

 

 

TP6-X

 

 

 

 

 

 

 

 

 

 

 

 

 

TP5-X

 

 

 

 

 

 

 

TP4-X

 

 

 

 

 

 

 

TP3-X

 

 

PIM 3

 

 

PIM 3

 

TP2-X

 

 

 

 

 

 

 

TP1-X

 

 

 

 

 

 

 

TP0-X

 

 

 

 

 

 

 

 

 

 

 

 

 

UTP CTG5 ST CA-K

 

FRONT VIEWI

 

CN

PIM 2

CN

CN

PIM 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FCH

 

FCH

FCH

 

 

 

 

FANU

 

 

FANU

 

 

 

 

 

 

 

 

 

 

 

PIM 1

 

 

 

 

PIM

1

 

 

 

 

 

UTP CTG5 ST CA-M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN

CN

 

CN

 

UTP CTG5 ST CA-M

CN

 

CN

PIM 0

PIM 0

 

 

CN

CN

UTP CTG5 CRS CA-F

CN

 

 

 

HUB

 

 

HUB

 

HUB

 

00 0102 03 04 05 06

00 0102 03 04 05 06

 

BSCM

 

 

BSCM

UTP CTG5 ST CA-J

 

CN

 

 

LPM

02 03 04 05 06LPM

00 0102 03 04 05

 

 

UTP CTG5 ST CA-J

 

 

CN

 

CN

 

 

BASEU

 

BASEU

 

 

Figure 4-15 Examples of Ethernet Cable Connection-FCH in PIM2 (1-IMG System) (1/2)

CHAPTER 4

ND-70185 (E)

Page 52

Revision 3.0

Page 67
Image 67
NEC NEAX2400 system manual Installation