TROUBLESHOOTING
23-S FCH Failure Notification (Detection)
7.1 Repair Procedure
STEP 1: Make sure that the related Ethernet cables are securely inserted into the connectors. (See the example shown below.) If not, securely insert the cable. In this instance, confirm whether System Message 23- T FCH Fault Recovery Notification is displayed as the result of cable insertion. If no fault is found in this step, move to STEP 2.
STEP 2: The following equipment is suspected to be faulty. Check for each item:
•Ethernet cables (10
•HUB
•FCH
DTI
FCH (PA-FCHA)
PIM 1
FCH card indicated bysystem message
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
HUB
PIM 0 | HUB |
|
LANI
: 10
Note: 10 on system configuration.
Figure 7-12 10 BASE-T Cable Connection Check
CHAPTER 7 |
Page 156
Revision 3.0