NEC NEAX2400 system manual EX-FCCSFeatures

Models: NEAX2400

1 213
Download 213 pages 13.1 Kb
Page 190
Image 190

EX- FCCS

EX-FCCS Features

3.EX-FCCS Features

3.1Number Portability

[Operating Procedure]

1.Log in to the NCN of the Center FUG from the Centralized-MAT for EX-FCCS.

2.Assign the Telephone Number data using AELGN command. The new data is automatically copied to the NDM in the self-FUG and the other FUG in an EX-FCCS network. AELGN command is also used to delete or change Telephone Number data in addition to assignment.

Note 1: AELGN command is used to operate Number Portability forTelephone Numbers used in NEAX2400 IMX systems. For the NEAX2000 IVS2 system, several commands are required for assignment. For details, see related NEAX2000 IVS2 manuals.

Note 2: When logging in to the node other than the NCN of the Center FUG (LN in Center FUG or LN/NCN in other FUGs), only reading out the AELGN command data is available.

Note 3: If the center FUG group is not “0” and FUG no.“0” is assigned to another group, AELGN command data assignment is available for the node to be logged in only.

[Service Conditions]

1.A closed numbering network is recommended for numbering plan of the EX-FCCS network.

2.Only Telephone Number (max. 8 digits) is allowed for the extension number used in an EX-FCCS network.

ND-70185 (E)CHAPTER 8

Page 175

Revision 3.0

Page 190
Image 190
NEC NEAX2400 system manual EX-FCCSFeatures