DATA PROGRAMMING

Assignment of FCH Related Data

STEP 3: MBCT

Unbusy the connection trunk data assigned in the previous step, by using the MBCT command. This is required for FCH, FGH trunks as well as speech channels.

STEP 4: AFCH

Assign FCH number on an FCH circuit card basis. In the following example, FCHN=1 is assigned for the FCH circuit card. For the FGH card, FCHN assignment is not necessary.

PBX

speech

RT1

DTI T1

 

 

 

 

FGH

 

signaling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT14

 

 

ROUTER

￿ Nail

 

 

 

 

 

 

Q-sig

Down

 

 

 

 

 

FCHN=1

Connection

 

 

 

 

 

 

 

 

 

 

FCHEN: 000030

 

 

 

FCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT13

 

 

 

 

AFCH command display

FCHN

1

 

FCHEN

 

000030

Note

Note: This setting is a sample.

to CPU

Figure 5-53 Assignment of FCHN (Example)

CHAPTER 5

ND-70185 (E)

Page 106

Revision 3.0

Page 121
Image 121
NEC NEAX2400 system manual Assignment of Fchn Example